Instruction manual

15
Fig. 3.10
Ring opening
Fig. 3.11
Ring opening
Regulation of air supply to oven and grill burners
Using a cross-head screwdriver, slacken the screw securing the air flow regulation collar
(fig. 3.10 and 3.11) and move the collar forward or backward to increase or reduce the
air aperture in accordance with gas type and the indications in the “
TABLE FOR THE
CHOICE OF THE INJECTORS
”.
Light the burner and check the flame.