User's Manual

4
"TAMPER" activates the tamper sensing. The Factory sets RAMV into Tamper mode when shipped.
"NOTAMPER" Disables the TAMPER sensing. Use this if working on installation and you don’t want to be
sent messages. Don’t forget to enable it when finished.
"SIREN" activates the SIREN / STROBE( if these are installed) upon a Geo-fence transgression. These are
accessories not normally supplied with RAMV. The sirens we supply will trigger on a pulse from RAMV and
remain on for a period set by an internal timer in the siren. Cutting the wires to the siren will not disable it
once activated.
"NOSIREN" disables the Siren and Strobe if issued before a transgression is activated. If the Siren is
already activated, it will not turn it off. It will be up to the siren internal timer to time-out and reset itself. This
command only stops further triggering of external alarm devices. Contact us for other programmable siren
activation options.
SPECIAL COMMANDS
"REPORT xy//info" sets RAMV up to send an AUTOMATIC "INFO" report every "xy" hours.
"TEMPRESET" alone, resets the Temperature Logs to present ambient temperature.
"TEMPRESET <>F(
or C)<> Max Temp// Min temp " F or C selects units, <> is a space, Max and Min
temps sets the maximum and Minimum ALERT temperatures, Range is 14 F (-10 C) to 176 F ( 80 C).F:
Fahrenheit,
C: Centigrade. Eg: TEMPRESET F 110//38
"HELP" responds with Help info on command syntax.
TEMPDEL n Temperature delay in minutes (n). Use to reduce transient alarms.
PWRDEL n Power loss alert delay in minutes (n). Use to reduce transient alarms.
ARM Activates SMS messaging ( Factory default)
DISARM Disables all SMS messaging.
ASK<>code Used in USSD enabled networks to request network subscriber data like prepaid simcard
balance amount. If code to get simcard dollar balance is say *120# from your cellphone,
then send RAMV the code as ASK *120# and it will return the network message with this
information. Does not work with voice-only services. Requires USSD service.
PLE Power Loss alert ENABLE.
PLD Power Loss alert DISABLE.
EXTVOLT ON//v.v Alarm voltage setpoint for low voltage alert. Sets value to send alarm.
Eg EXTVOLT ON//11.8 Use in conjunction with PWRDEL delay time value to avoid
transient alarms. OFF/ON.
E1D n Add a Time delay of n minutes to switch n. Use to avoid transient alarms.
DATARESET Resets configuration to Factory default. Use with care. Custom changes will be lost.
CTXSO<n><space><msg> Change Switch (n) OPEN message to "msg".
CTXSC<n><space><msg> Change Switch (n)CLOSED message to " msg".
COMMAND STRINGS
RAMV will accept multiple commands in the same text message as long as they are each separated by a
semi colon.
eg; GETSIG;INFO;TAMPER;SIREN;FIX
QUESTIONS and TROUBLESHOOTING
Please refer to our website for Frequently asked questions and troubleshooting guidelines.