Installation guide

Enclosure Object and Element Commands
www.lsi.com/channel/products 115
/cx/ex show all
The /cx/ex/show all command applies only to 9750 and 9690SA controllers.
For the 9650SE, simply drop the prepended controller name in the command
and use /ex.
The /cx/ex/show all command shows the current settings of all attributes for
enclosure /cx/ex.
/cx/ex/slotx show
The /cx/ex/slotx show command applies only to 9750 and 9690SA
controllers. For the 9650SE, simply drop the prepended controller name in the
command and use /ex.
The /cx/ex/slotx show command shows information about the specified /slotx
on the specified enclosure /ex. The slot name is followed by its status. If the
slot contains a drive and no fault is detected, the status is OK. If the slot is
empty the status indicates NO-DEVICE. The port that is correlated to the slot
is indicated in the next column. If the slot is empty, then a dash (-) is shown in
the Port column. The final column shows the Identify setting for the specified
slot. The following is an example of the output:
Example:
//localhost> /c0/e0/slot1 show
Slot Status Port Identify
----------------------------------------------------
slot1 OK /c0/p1 Yes
/cx/ex/slotx show identify
The /cx/ex/slotx show identify applies only to 9750 and 9690SA controllers.
For the 9650SE, simply drop the prepended controller name in the command
and use /ex.
The /cx/ex/slotx show identify command shows the identify status of the
specified slot. The status can be either on or off. If identify is on, the LED
associated with the slot blinks. If the enclosure does not support Slot Identify,
this command returns N/A.
Example:
//localhost> /c0/e0/slot1 show identify
/c0/e0/slot1 Identify status = on