Owner manual

Programming
11
MC22-GB-V1.00
r. rpt
Meaning: repetitions remaining to the end
Range: - from 0 to 9999 and then inF
The figure shows the remaining repetitions after the current
execution.
For example 0 means that the program stops at the end of the
current execution, while inF means that the device is set for
endless repetitions.
Available: only when the programmer state is run or hold and the “Program
execution repetitions” parameter is different from 0
Alterable: never
rpt
Meaning: time remaining to the end of the program, considering also the
remaining repetitions
Range: - from 1 second to 99 min 59 sec
the upper display shows 12.30 (12 min 30 sec)
the lower display shows rpt.S
- from 1 h 40 min to 99 h 59 min
the upper display shows 18.45 (18 h 45 min)
the lower display shows rpt.H
- from 100 to 9999 hours
the upper display shows 125 (125 h)
the lower display shows rpt.H
- over 9999 hours
the upper display shows %%%%
the lower display shows rpt.H
Available: only when the programmer state is run or hold and the “Program
execution repetitions” parameter is different from 0
Alterable: never
itSp, Sp. 1, rr. 1, TH. 1, SP 2, tH. 2, Sp. 3, rr. 3 , tH. 3 , Sp. 4 , rr. 4 , tH. 4. (see Section
4.2 for details)
Available: only when the programmer state is run or hold for review only.
Alterable: only in OP.P mode
4.2 Program editing
To select the program to edit, change the nPrg parameter to show the program you wish to
edit.
Then access the Program edit operative mode OP.P to address the below parameters:
(The normal 10 s timeout is removed during monitor / modify the program parameters)
pass
Meaning: password to enable editing of program 1, 2, 3
Range: 0 up to 999
Available: The programmer state is idle and program select is 1 or 2 or 3 alterable: