Owner manual

Programming
21
MC22-GB-V1.00
5 Enhanced Mode
In enhanced mode the following parameters are available.
CUSTOMER CALIBRATION TYPE SELECTION
Identification code: CL.st
Range: FACt Factory calibration (a = 1 b = 0)
C.CL1 1 point calibration (a = 1 b = OFSt)
C.CL2 2 point calibration (a = x b = x)
C.CL3 2 coefficients calibration (a = SLOP b = OFSt)
OFFSET
(This parameter is always available but can be modified only if CL.ST = C.CL1, C.CL3)
Identification code: OFSt
Range: -199.9 / 199.9
SLOPE
(This parameter is always available but can be modified only if CL.ST = C.CL3)
Identification code: SLOP
Range: 0.500 / 2.000
LOW POINT CALIBRATION
(This parameter is available only if CL.ST = C.CL2)
Identification code: CaL.L
Range: Value in engineering units between min / max range value
OFFSET ON LOW POINT
(This parameter is available only if CL.ST = C.CL2)
Identification code: OFS.L
Range: -199.9 / 199.9
HIGH POINT CALIBRATION
(This parameter is available only if CL.ST = C.CL2)
Identification code: CaL.H
Range: Value in engineering units between min / max range value
OFFSET ON HIGH POINT
(This parameter is available only if CL.ST = C.CL2)
Identification code: OFS.H
Range: -199.9 / 199.9
MODBUS ADDRESS
Identification code: adr
Range: 0 (Interface disable) 1 up to 254