Operating Instructions Temperature Indicator with Digital Communications Type 3216cc English MC23-GB – v1.
Contents 1 INTRODUCTION TO THE CONTROLLER AND MANUAL 1.1 2 DESCRIPTION 3 BASIC OPERATION 4 2.1 2.2 2.3 3 DIGITAL COMMUNICATIONS – RS232 DIGITAL COMMUNICATIONS – RS485 COMMS ADDRESS NAVIGATION DIAGRAM 6.1 7 CUSTOMER ID. UNITS SCROLLING TEXT DIGITAL COMMUNICATIONS 5.1 5.2 5.3 6 UNDERSTANDING USER LEVELS SETTING UP THE CONTROLLER 4.1 4.2 4.3 5 CONTROLLER LAYOUT (HOME DISPLAY) KEYS OPERATION USER LEVELS 3.1 4 3 3216CC INDICATOR CONTROLLER FAULT 7.
Quick Start Guide 1 Introduction to the Controller and Manual 1.1 Description The model 3216 controller/indicator is made by Eurotherm, and is fitted by Carbolite configured for immediate use as an indicator. It is configured for the input (thermocouple) type for which it was ordered. The indicator does not contain a real-time calendar, and is not subject to century-end date problems. When the indicator is supplied fitted into a furnace or oven then it is usually on whenever the Instrument Switch is on.
Quick Start Guide 2 Basic Operation 2.1 Controller Layout (Home Display) Power Output Indicator Measured Temperature Alarm Indicator Remote Indicator (When configured) Scroll PageKey Key 2.2 Scroll Key Up Key Down Key Keys Page Key Scroll Key ACK Page + Scroll Arrow Keys The Page key is used to access level 2 when held down for 3 seconds. The Scroll key is used to scroll through the parameters.
Quick Start Guide 3 User levels 3.1 Understanding User Levels There are two user levels in the controller; Level 1(Operator) and Level 2 (Supervisor). Level 1 (Operator) is for the day to day operation of the controller. These parameters are not protected by a security code. Level 2 (Supervisor) provides access to additional parameters. Access to these is protected by a security code To Enter Level 2 1. Press and hold the page key for 3 seconds. 2. The display will show Leu 1 GOTO 3.
Basic Operation 4 Setting up the controller Before using the controller (or during its lifetime) certain parameters may have to be set, depending on specific requirements. To do this the controller must be set to supervisor level (Level 2) see section 3.1 4.1 Customer ID. A furnace or oven identification number can be entered if required. This maybe used to identify one of many units, for production or quality control systems. Press scroll until the display shows ID .
Options 5 Digital Communications 5.1 Digital Communications – RS232 If the RS232 option is supplied, then the furnace is fitted with one subminiature D-socket connected to the controller communications (comms) module. RS232 is suitable for direct connection to a personal computer (PC), using a “straight through” cable as follows (the linked pins at the computer end are recommended but may not be necessary).
Controller Fault 6 Navigation Diagram 6.1 3216cc indicator LEVEL 1 ACCESS Pass code = 9 3 Sec PV LEVEL 2 LEV GOTO ID PV TEXT ADDR ID UNITS 7 Controller Fault 7.1 Fault Code Diagnostic Table Error Code S.