Product Overview

m 19,000-volt output for smoother
ignition
m Solid state technology yields high
performance, long life and durability
m Constant-duty rated
m Low current draw saves electricity
m Epoxy sealant provides water
resistance and heat dissipation
m Consistent voltage output across a
wide range of input voltages
Installing and wiring
Carlin ignitors and ignitor kits must be
installed and serviced only by a qualified burner service
technician. Always disconnect power source before
wiring to avoid electrical shock or damage to electrical
components.
1. Carlin 41000 series ignitors can be mounted directly on
top of the burner housing or other location, in the same
manner as standard transformers.
2. Disconnect electrical power to the burner. Disconnect
wires from primary control to existing ignition transformer
or ignitor.
3. Remove any screws securing ignition transformer or
ignitor.
4. Observe the routing of electrical wiring from burner junc-
tion box to ignition transformer or ignitor.
5. Remove existing ignition transformer or ignitor.
6. Select and install the appropriate terminals/springs based
on the burner application. If the appropriate terminals are
not included, remove and reuse the terminals from the
ignitor being replaced.
IMPORTANT: Make sure to align terminals so that they
make good contact with the electrode rods. In some
cases properly aligned terminals will not be parallel to
each other.
7. Install new ignitor, reversing the above steps. Install, con-
nect and route the ignitor wiring the same as the original
ignition transformer or ignitor wiring was installed.
8. Make sure the ignitor is firmly attached and that all electri-
cal connections meet local codes before applying power.
Field check
Never test an ignitor by placing a screw-
driver (or other metallic object) across the high voltage
clips.
MODEL 41000
Electronic Ignitor
19-KV continuous-duty
Data Sheet
Ignitor Model 41000
Power Input 120 VAC, 60 HZ, 40 VA
Ignitor Output 19 KV, 35 mA RMS
Secondary Grounding Midpoint
Operating Temperature Limits +32°F to +140°F
Storage Temperature Limits -40°F to +185°F
Agencies UL Recognized U.S.
and Canada
MN41000AC 113016© Copyright 2016 — Carlin Combustion Technology, Inc.
TECH SUPPORT HOTLINE 800-989-2275