Datasheet
12
Carlo Gavazzi Industri A/S
CA18CAxxBPxIO - IO-Link
CA18CAxxBPxIO ENG26/08/2019
*See operation diagram
LED indication
LED indications
• LED Indication disabled
• LED Indication enabled
Factory settings: LED Indication enabled
Environmental
Ambient temperature
-30°C... +85°C (-22°F... +185°F) Operating
-40°C ... +85°C (-40°F ... +185°F) Storage
Max. temperature on sensing face 120°C (248°F)
Ambient humidity range
35% ... 95% Operating
35% ... 95% Storage
Vibration 10 ... 150 Hz, 1 mm / 15 G EN 60068-2-6
Shock 30 G / 11ms, 3 pos, 3 neg per axis EN 60068-2-27
Drop test
2 x 1m
100 x 0,5m
EN 60068-2-31
Rated impulse withstand voltage ≥2 kV with 500 Ω
Overvoltage category III IEC 60664, EN 60947-1
Pollution degree 3 IEC 60664, 60664A; EN 60947-1
IP rating
IP 67, IP 68/60 min., EN 60529; EN 60947-1
IP69K* DIN 40050-9
NEMA Enclosure Types 1, 2, 4, 4X, 5, 6, 6P, 12 NEMA 250
Tightening torque ≤ 2.6 Nm
* The IP69K test according to DIN 40050-9 for high-
pressure, high-temperature wash-down applications.
The sensor must not only be dust tight (IP6X), but
also able to withstand high-pressure and steam
cleaning. The sensor is exposed to high pressure
water from a spray nozzle that is fed with 80°C water
at 8’000– 10’000 KPa (80–100bar) and a ow rate of
14–6L/min. The nozzle is held 100 –150 mm from the
sensor at angles of 0°, 30°, 60° and 90° for 30s each.
The test device sits on a turntable that rotates with
a speed of 5 times per minute. The sensor must not
suer any damaging eects in appearance or function
from the high pressure water function.
TRIPLESHIELD
TM
Exceeding the norms for capacitive sensors.