Datasheet
5
Carlo Gavazzi Industri A/S
CA18CAxxBPxIO - IO-Link
CA18CAxxBPxIO ENG26/08/2019
Sensing
Detection
Sensor front Selector
A
Logic
A - B
Time
delay
Output
inverter
Sensor
output
One of
1 to 6
AND, OR,
XOR, S-R
divider
ON, OFF
One-shot
N.O., N.C. NPN, PNP,
Push-Pull
Selector
B
Logic
A - B
Time
delay
Output
inverter
Sensor
output
One of
1 to 6
AND, OR,
XOR, S-R
divider
ON, OFF
One-shot
N.O., N.C. NPN, PNP,
Push-Pull
EXT-Input
S.P., Two P.
Window,
Adj. Hyst.
1. SSC1
S.P., Two P.
Window,
Adj. Hyst.
2. SSC2
3. Dust 1
4. Dust 2
5. Temp
6. EXT-Input
A
B
A
B
Out 1
Out 2
EXT-
Input
Sensor switching channel SSC1 and
SSC2
SSC1
• Enabled
• Disabled
Factory settings: Enabled
SSC2
• Enabled
• Disabled
Factory settings: Enabled
Switching mode
SSC1
• Deactivated
• Single point mode
• Two point mode
• Windows mode
Factory settings: Single point mode
SSC2
• Deactivated
• Single point mode
• Two point mode
• Windows mode
Factory settings: Single point mode
Rated operating distance (S
n
)
0 - 12 mm (Factory settings: 12
mm), (ref. target 36x36 mm ST37, 1
mm thick, grounded)
Non-ush-mounted sensor
0 - 8 mm (Factory settings: 8 mm),
(ref. target 24x24 mm ST37, 1 mm
thick, grounded)
Flush-mounted sensor
Sensitivity control
Adjustable by potentiometer, external teach or by IO-Link settings
• Potentiometer disabled
• Potentiometer enabled
• External teach
Factory settings: Potentiometer enabled
Potentiometer
Electrical adjustment 11 turns
Mechanical adjustment 16 turns
Adjustable distance
2 ... 10 mm (ush types)
Factory settings: SP1 1000 and SP2 10000
3 ... 15 mm (Non- ush types)
Factory settings: SP1 1000 and SP2 10000
Eective operating distance (S
r
) 0.9 x S
n
≤ S
r
≤ 1.1 x S
n
Usable operating dist. (S
u
)* 0.85 x S
r
≤ S
u
≤ 1.15 x S
r
Hysteresis (H)
CA18CAF08…
CA18CAN12…
Adjustable by IO-Link (1% to 100%)
Factory settings: Typical 6%
Factory settings: Typical 15%
Detection lter
This function can increase the immunity towards unstable targets and
electromagnetic disturbances: Value can be set from 1 to 255.
Factory settings: 1
(1 is max. operating frequency and 255 is min. operating frequency)