Datasheet
Specifications are subject to change without notice (21.11.03) 3
Teach-in Guide
Adjustment - Background
No target present
Push-button
LED - Green
LED - Yellow
Time (sec)
Press push-button >3 seconds until LED´s are flashing one time per second. The background will be calibrated when the
push-button is released during the following 3 seconds
Adjustment - Object
Target present
Push-button
LED - Green
LED - Yellow
Time (sec)
Press push-button >6 seconds until LED´s are flashing two times per second. The object will be calibrated when the push-
button is released during the following 3 seconds
Adjustment - NO - NC
Push-button
LED - Green
LED - Yellow
Time (sec)
0 1 2 3 4 5 6 7 8 9 10 11 12 13
Press push-button >9 sec. until LED´s are flashing three times per second. The status of NO-NC will toggle when the push-
button is released during the following 3 seconds
BN+
BK
WH
BU-
Wiring Diagrams
I
LOAD
< 250mA
I
ALARM
< 20mA
Teach-in
The PNP- or NPN-load will automatically be
detected.
By means of the Teach-in wire, the functions
described in the Teach-in Guide can be set-
up.
It is possible to Teach-in more sensors at the
same time by connecting the WH-wires in
parallel to the common ”-” supply.
(#): Plug connections
Important: If alarm output (WH-wire) is
unused, it has to be terminated to +supply
0 1 2 3 4 5 6 7 8 9 10 11 12 13
0 1 2 3 4 5 6 7 8 9 10 11 12 13
Releasing the push-button after 12 sec. returns the sensor to factory settings.
(1)
(3)
(2)
(4)
CA, M18, M30, DC, Teach-in