Datasheet

Specifications are subject to change without notice (25.06.99) 1
Rated operating dist. (S
n
)
CA18CLF08 3 to 8 mm
factory set at 8 mm
CA18CLN12 3 to 12 mm
factory set at 12 mm
Sensitivity Adj. 270° turn pot. meter
Effectiv operation dist. (S
r
) 0.9 x S
n
S
r
1.1 x S
n
Usable operation dist. (S
u
) 0.8 x S
r
S
n
1.2 x S
r
Repeat accuracy (R) 5%
Hysteresis (H)
4 to 20% of sensing distance
Rated operational volt. (U
B
) 20 to 250 VAC
(ripple included)
Ripple 10%
Rated operational current (I
e
)
Continuous 500 mA
Short-time < 2.5 A (max. 20 ms)
Min. load current 10 mA
Voltage drop (U
d
) 10 VAC (at loads 20 mA)
Protection Reverse polarity,
short-circuit, transients
Power ON delay 100 ms
Frequency of operating
cycles (f) 10 Hz
Indication for output ON LED, yellow
Environment
Degree of protection IP 67 (Nema 1, 3, 4, 6, 13)
Temperature
Operating temperature
-25° to +80°C ( -13° to +176°F)
Storage temperature
-40° to +85°C (-40° to +185°F)
Housing material
Body Grey, thermoplastic polyester
Front Grey, polyester
Cable end Polyester
Nuts Black, reinforced nylon
Connection
Cable Grey, 2 m, 2 x 0.5 mm
2
Oil proof PVC
Plug (M6) M12 x 1, double keyed
Cable for plug (M6) CON.6A-series
Weight
Cable version 110 g
Plug version 30 g
Approvals
UL, CSA
CE-marking Yes
Type Selection
Product Description
Proximity Sensors Capacitive
Thermoplastic Polyester Housing
Type CA, M18, AC
• Featuring
TRIPLESHIELD
sensor protection
Adjustable sensing distance 3-8 mm or 3-12 mm
Rated operational voltage: 20-250 VAC
Output: SCR
Make or break switching function
LED indication
High noise immunity
Flush and non-flush types
Plug and cable versions
DC versions in the same housing
Capacitive proximity switches
with either sensing distance 8
mm flush mounted in metal or
sensing distance 12 mm non-
flush mounted. 2-wire AC out-
put with make (NO) or break
(NC) switching. Grey M18 po-
lyester housing with 2 m
PVC cable or M12 plug. Ideal
for use in level and plastic
machinery applications.
Housing Rated Mounting Ordering no. Ordering no. Ordering no. Ordering no.
diameter operating SCR/cable SCR/plug SCR/cable SCR/plug
dist. (S
n
)
1)
Make Make Break Break
switching switching switching switching
M18 8 mm
Flush (built-in)
CA18CLF08TO CA18CLF08TOM6 CA18CLF08TC CA18CLF08TCM6
M18 12 mm Non-flush CA18CLN12TO CA18CLN12TOM6 CA18CLN12TC CA18CLN12TCM6
1)
Object: Grounded steel plate
Specifications
TRIPLESHIELD
Type
Housing style
Housing size
Housing material
Housing length
Detection principle
Sensing distance
Output type
Output configuration
Connection type
Ordering Key
CA18CLN12TOM6

Summary of content (2 pages)