Datasheet
2 Specifications are subject to change without notice (24.06.2014)
CA30CAN/CAF.....
Specifications (cont.) EN 60947-5-2
Repeat accuracy (R) ≤ 5%
Hysteresis (H)
3 - 20%
Rated operational volt. (U
B
) 10 to 40 VDC (ripple incl.)
Ripple ≤ 10%
Output function NPN or PNP
Output switching function N.O. and N.C.
Rated operational current (I
e
) ≤ 200 mA (continuous)
Capacitive load 100 nF
No-load supply current (I
o
) ≤ 12 mA
Voltage drop (U
d
) ≤ 2.0 VDC @ 200 mA DC
Minimum operational
current (I
m
) ≥ 0.5 mA
OFF state current (I
r
) ≤ 100 μA
Protection Short-circuit, reverse
polarity, transients
Frequency of operating
cycles (f) 50 Hz
Response time OFF-ON (t
on
) ≤ 10 ms
Response time ON-OFF (t
off
) ≤ 10 ms
Power ON delay (t
v
) ≤ 200 ms
Indication
For output ON LED, yellow
Power and signal stability LED, green
Environment
Installation category III (IEC 60664, 60664A;
60947-1)
Degree of pollution 3 (IEC 60664, 60664A;
60947-1)
Degree of protection IP 67, IP 68/60 min., IP69K*
(IEC 60529; 60943-1)
NEMA type 1, 2, 4, 4X, 5, 6, 6P, 12
Operating temperature
-30 to +85°C ( -22 to +185°F)
Max. temperature on sensing face 120°C (248°F)
Storage temperature
-40 to +85°C (-40 to +185°F)
Rated insulation voltage 1 kVAC (rms)
IEC protection class III
Tightening torque ≤ 7.5 Nm
Connection
Cable PVC,
Ø5.2 x 2 m, 4 x 0.34 mm
2
Oil proof, grey
Plug (M1) M12 x 1, - 4 pin
Temperature alarm output 60ºC ± 5ºC
Response time examples
T
A
= 25°C 16 sec @ T
EXC
= 800°C
390 sec @ T
EXC
= 80°C
TRIPLESHIELD
TM
Exceeding the norms for
capacitive sensors
Electrostatic discharge
(EN61000-4-2)
Contact discharge > 40 kV
Air discharge > 40 kV
Electrical fast transients/burst
(EN 61000-4-4) ±4kV
Surge
(EN 61000-4-5)
Power-supply > 2kV (with 500 Ω)
Sensor output > 2kV (with 500 Ω)
Wire conducted disturbances
(EN 61000-4-6) > 20 Vrms
Power-frequency magnetic
fields (EN 61000-4-8)
Continous > 60 A/m, 75.9 µ tesla
Short-time > 600 A/m, 759 µ tesla
Radiated RF electromagnetic
fields (EN 61000-4-3) > 20 V/m
Shock (IEC 60068-2-27) 30 G / 11ms, 3 pos, 3 neg
per axis
Rough handling shocks
(IEC 60068-2-31) 2 times from 1m
100 times from 0,5m
Vibration (IEC 60068-2-6) 10 to 150 Hz, 1 mm / 15 G
Housing material
Body PBT, grey,
30% glass reinforced
Cable gland PA12, black
Fingernuts PA12, black
Trimmershaft Nylon
Weight
Cable version 190 g
Plug version 106 g
Approvals cULus (UL508)
CE-marking Yes
MTTF
d
829 years @ 40°C (+104°F)
* The IP69K test according to DIN 40050-9 for high-pressure, high-temperature wash-down applications.
The sensor must not only be dust tight (IP6X), but also able to withstand high-pressure and steam cleaning.
The sensor is exposed to high pressure water from a spray nozzle that is fed with 80°C water at 8’000–
10’000 KPa (80–100bar) and a flow rate of 14–6L/min. The nozzle is held 100 –150 mm from the sensor at
angles of 0°, 30°, 60° and 90° for 30s each. The test device sits on a turntable that rotates with a speed of 5
times per minute. The sensor must not suffer any damaging effects from the high pressure water in appear
-
ance and function.
90°
60°
30°
0°