Datasheet
6
Carlo Gavazzi Automation S.p.A.
ICB12, ICB18 & ICB30 IO-Link 3-wire DC
ICB12, ICB18 & ICB30 IO-Link 3-wire DC DS EN21/05/2018
Sensing
Detection
Rated operating distance S
n
4 to 22 mm: depending on housing diameter and version (ush or non-ush)
Reference target
The operating distance is measured according to IEC 60947-5-2, using a
standard target moving axially.
This target is square shape 1 mm thickness, made of steel e.g. type Fe 360
as dened in ISO 630 and it shall be of the rolled nish.
The length of the side of the square is equal to
– the diameter of the circle inscribed on the active surface of the sensing face,
or
– three times the rated operating distance S
n
whichever is greater
Assured operating sensing distance
(S
a
)
0 ≤ S
a
≤ 0.81 x S
n
(e.g. with S
n
of 4 mm, S
a
is 0 ... 3.24 mm)
Eective operating distance (S
r
) 0.9 x S
n
≤ S
r
≤ 1.1 x S
n
Usable operating distance (S
u
) 0.9 x S
r
≤ S
u
≤ 1.1 x S
r
Hysteresis (H) 1...20%
Y
X
S
T
S: sensor
T: target
-0,020 0,02 0,04 0,06 0,08 0,10,120,140,16
-0,32
-0,21
-0,11
0
0,1
0,21
0,31
-8
-6
-4
-2
0
2
4
6
8
-0,5 00,5 11,5 22,5 33,5 44,5
Distance [Inches]
[Inches]
[mm]
Distance [mm]
S
T
00,040,080,120,160,2 0,24 0,28 0,32
-0,55
-0,37
-0,18
0
0,18
0,37
0,55
-12
-8
-4
0
4
8
12
012345678
Distance [Inches]
[Inches]
[mm]
Distance [mm]
S
T
Fig. 1 M12 Flush
Fig. 2 M12 Non-ush
-0,020,020,060,1 0,14 0,18 0,22 0,26 0,3
-0,55
-0,37
-0,18
0
0,18
0,37
0,55
-12
-8
-4
0
4
8
12
0 12345678
Distance [Inches]
[Inches]
[mm]
Distance [mm]
S
T
-0,2 -0,1 00,1 0,20,3 0,40,5 0,6
-0,76
-0,38
0
0,38
0,76
-24
-16
-8
0
8
16
24
-4 -2 02468101214
Distance [Inches]
[Inches]
[mm]
Distance [mm]
S
T
Fig. 3 M18 Flush Fig. 4 M18 Non-ush