Datasheet
Specifications are subject to change without notice (09.12.2008) 5
Teach functions
Normal operation, optimized switching point
1
. Line up the emitter and receiver. Yellow LED and
Green LED are ON.
2. Press the button for 3 seconds until both LEDs
flashes simultaneously.
(
The first switch point is stored)
3. Place the object between the emitter and receiver in
the detection zone.
4. Press the button once and the sensor is ready to
operate (Green LED ON, Yellow LED ON)
(The second switch point is stored)
For maximum sensing distance
(default setting)
1. Line up the emitter and receiver, place the object
between the emitter and receiver in the detection
zone. Yellow LED is OFF and Green LED is ON.
2. Press the button for 3 seconds until both LEDs
flashes simultaneously.
(The first switch point is stored)
3. Press the button a second time and the sensor is
ready to operate (Green LED ON, Yellow LED ON)
(The second switch point is stored)
For minimum overhead
(Transparent or semi-transparent objects)
1. Line up the emitter and receiver. Yellow LED and
Green LED are ON.
2. Press the button for 3 seconds until both LEDs
flashes simultaneously.
(The first switch point is stored)
3. Press the button a second time and the sensor is
ready to operate (Green LED ON, Yellow LED ON)
(The second switch point is stored)
For dynamic set-up (running process)
1
. Line up the emitter and receiver. Green LED is ON,
status on the yellow LED is not important.
2. Press the button for 3 second until both LEDs flashes
simultaneously.
(
The first switch point is stored)
3. Press the button a second time and keep the button
pressed for at least one process cycle, release the
button and the sensor is ready to operate (The second
switch point is stored)
For make or break set-up
1. Press the button for 10 seconds, until the green LEDs
flashes.
2. While the green LED flashes, the output is inverted
each time the button is pressed. Yellow LED indicates
N.O. function selected.
If the button is not pressed within the next 10
seconds, the current output is stored.
PD30CNT15....MU/RT
12 4
3 sec. Push once
3
12 3
3 sec. Push once
12
3 sec. Push once
3
12
3 sec. Push once
3
10 sec.
12
Push once