Datasheet

Solid State Relay
Number of poles
Switching Mode
Rated Operational Voltage
Control voltage
Rated Operational current
Connection type for control
Connection type for power
Connection configuration
Option
Specifications are subject to change without notice (30.06.2011) 1
Product Width ranging from 17.5mm up to 70mm
Rated Operational voltage: Up to 600VAC
Rated Operational current: Up to 85AAC @ 40°C
Up to 6600A²s for I²t and 1200Vp blocking voltage
Control voltages: 3-32 VDC, 20-275 VAC (24-190 VDC)
IP20 protection
Design according to EN/IEC60947-4-2, EN/IEC60947-4-3,
EN/IEC62314, UL508, CSA 22-2 No. 14-10
Integrated voltage transient protection with varistor
RoHS compliant
Short circuit current rating: 100kA
VDE approval
Germanischer Lloyd approval
1
Product Description
Ordering Key
This new range of solid state
contactors presents a unique
opportunity to maximize effi-
ciency in panel space and is an
evolution of solid state switch-
es for which Carlo Gavazzi is
very well known.
The nominal current ratings
are at 40˚C. The smallest
width is 17.5mm and is rated
at 20 AAC. Power and control
teminals allow for safe looping
of cables.
Solid State Relays
Zero Switching
Types RGC Solid State Contactor 'E' Connection
RGC 1 A 60 A 30 K K E _
V
oltage transient protection is standard across the output with a varistor.
S
pecifications are stated at 25°C unless otherwise noted.
1. Germanischer Lloyd approval applicable only to models RGC1....15.KE,
RGC1...20.KE and RGC1....30.KE
Ordering Key
1Phase SSR Rated Voltage Control Voltage Rated Connection Connection Connection
with heatsink Current
2
Control Power Configuration Option
RGC1A: ZC 23: 230V +10% - 15%, 800Vp D: 3 or 4-32VDC 15: 20AAC K: Screw K: Screw E: Contactor P: Overtemperature
RGC1B: IO 60: 600V +10% -15%, 1200Vp A: 20 - 275VAC, 24-190 VDC 20: 23AAC G: Box clamp G: Box Clamp protection
3
30: 30AAC M: Pluggable
40: 40AAC spring-loaded
60: 60AAC
90: 85AAC
2. Refer to derating curves
3. Default control connection for RGC...P is Box Clamp. See connections specifications.
Selection Guide (ZC= Zero Cross Switching, IO = Instant-On Switching, OTP= Over Temperature Protection )
Rated Output Blocking Connection Control Rated Operational Current @ 40˚C
Voltage Voltage Control/ Power Voltage 20 AAC 23 AAC 23AAC + OTP 30 AAC 30AAC + OTP
230VAC, ZC 800Vp Screw
3
/Screw 3 - 32VDC
4
RGC1A23D15KKE RGC1A23D20KKE RGC1A23D20GKEP RGC1A23D30KKE RGC1A23D30GKEP
Spring/Screw 3 - 32VDC RGC1A23D15MKE RGC1A23D20MKE - RGC1A23D30MKE -
Screw /Screw 20 - 275VAC, RGC1A23A15KKE RGC1A23A20KKE - RGC1A23A30KKE -
24 - 190VDC
Spring/Screw 20 - 275VAC, RGC1A23A15MKE RGC1A23A20MKE - RGC1A23A30MKE -
24 - 190VDC
600VAC, ZC 1200Vp Screw
3
/Screw 4 - 32VDC
4
RGC1A60D15KKE RGC1A60D20KKE RGC1A60D20GKEP RGC1A60D30KKE RGC1A60D30GKEP
Spring/Screw 4 - 32VDC RGC1A60D15MKE RGC1A60D20MKE - RGC1A60D30MKE -
Screw
3
/Screw 20 - 275VAC, RGC1A60A15KKE RGC1A60A20KKE RGC1A60A20GKEP RGC1A60A30KKE RGC1A60A30GKEP
24 - 190VDC
Spring/Screw 20 - 275VAC, RGC1A60A15MKE RGC1A60A20MKE - RGC1A60A30MKE -
24 - 190VDC
600VAC, IO 1200Vp Screw/Screw 4 - 32VDC RGC1B60D15KKE RGC1B60D20KKE - RGC1B60D30KKE -
4. DC control voltage range for RGC..D..P is 5 - 32VDC