Datasheet
Specifications are subject to change without notice (07.10.2003) 1
Type Rated operational Rated operational Control voltage
voltage U
e
current I
e
U
c
*)
RSE: E-series, 22: 127/220 VACrms, 50/60 Hz 03: 3 A -B: 24 to 110 VAC/DC
motor controller 40: 230/400 VACrms, 50/60 Hz 12: 12 A & 110 to 480 VAC
48: 277/480 VACrms, 50/60 Hz
60: 346/600 VACrms, 50/60 Hz
*) The control voltage should never be higher than the rated operational voltage.
Solid State Relay
Motor controller
E-line housing
Rated operational voltage
Rated operational current
Control voltage
Ordering Key
Motor Controllers
AC Semiconductor Motor Controller
Types RSE 22 .. - B, RSE 4. .. - B, RSE 60 .. - B
RSE 40 03 - B
• Soft starting and stopping of 3-phase
squirrel cage motors
• Rated operational voltage: Up to 600 VACrms, 50/60 Hz
• Rated operational current: 3 A or 12 AAC 53 b
• Potential-free control input
• LED-indications for supply and operation
• Transient overvoltage protection built-in
•Integral bypassing of semiconductors
Product Description
Compact easy-to-use AC
semiconductor motor con-
troller. With this controller 3-
phase motors with nominal
load currents up to 12 A can
be soft-started and/or soft-
Type Selection
stopped. Starting and stop-
ping time as well as initial
torque can be independently
adjusted by built-in potentio-
meters.
Input Specifications (Control Input)
Control voltage U
c
A1-A2: 24 - 110 VAC/DC ±15%,
12 mA
A1-A3: 110 - 480 VAC ±15%,
5 mA
Rated insulation voltage 630 V rms
Overvoltage cat. III (IEC 60664)
Dielectric strength
Dielectric voltage 2 kVAC (rms)
Rated impulse withstand volt. 4 kV (1.2/50 µs)
Output Specifications
Utilization category AC-53b Integral bypassing
of semiconductors
Overload current profile
(overload relay trip class)
RSE ..03-B 3A: AC-53b:3-5:30
RSE ..12-B 12A: AC-53b:3-5: 180
Min. load current
RSE ..03-B 100 mAAC rms
RSE ..12-B 200 mAAC rms