Datasheet

Specifications are subject to change without notice (02.03.2006) 1
Sensor for liquid level detection
Built-in amplifier, Ga-As diode
Output: Transistor NPN/PNP or SCR, NO or NC
High chemical resistance to most acids and bases
VP01/03: Output OFF when sensor in liquid
VP02/04: Output ON when sensor in liquid
No electrical or thermal connection between liquid
and electrical circuit
LED-indication for output ON
Power supply: DC types: 10 to 40 VDC
AC types: 110 or 230 VAC
Photoelectrics
Product Description
Optical level sensor with un-
modulated, infrared light for
the detection of liquids. Fit-
ted with built-in amplifier.
Transmitter and receiver are
completely self-contained in
solid plastic housing designed
for mounting into container
wall. VP01/02 are available
in a Polysulphone housing
resistant to most acids and
bases. VP03/04 are avail-
able in a Polyamide 12
housing resistant to various
solvents.
Type
Housing
Output status
Output type
PNP output
Type Selection - DC Types
Housing material Ordering no. Ordering no. Ordering no. Ordering no.
Transistor NPN Transistor NPN Transistor PNP Transistor PNP
Make switching Break switching Make switching Break switching
Polysulphone VP 02 E VP 01 E VP 02 EP VP 01 EP
Polyamide 12 VP 04 E VP 03 E VP 04 EP VP 03 EP
Type Selection - AC Types
Housing material Ordering no. Ordering no. Ordering no. Ordering no.
Make switching Break switching Make switching Break switching
110 VAC 110 VAC 230 VAC 230 VAC
Polysulphone VP 02-110TB VP 01-110TB VP 02-230TB VP 01-230TB
Specifications
Transistor NPN/PNP SCR output AC types
Rated operational voltage 10 - 40 VDC 110 VAC: 100 - 121 VAC, 45 - 60 Hz
230 VAC: 195 - 265 VAC, 45 - 60 Hz
Rated operational current
Continuous 200 mA 10 - 100 mA
Voltage drop 1.0 VDC 9.0 VAC
No-load supply current 12 mA 7 mA
Sensing accuracy
Liquid level difference Horizontal mounting: ± 5 mm Horizontal mounting: ± 5 mm
Vertical mounting: ± 2.5 mm Vertical mounting: ± 2.5 mm
Ambient light 0 - 100 lux 0 - 100 lux
Frequency of operating cycles (f) 30 Hz 5 Hz