■ Data logging
This function enables the logging
of the required variables in the data
logging.
1) Choose the function DATA LOG-
GING by means of the and
keys, press to confirm;
2) select “DMD VARIABLES” by
means of the and keys and
confirm with ;
3) the display shows the window with
the list of the available DMD variables:
select the required available (ON) vari-
able by means of the and
keys and confirm with . To go
back to the main menu press .
To select the integration time
reapeat step 1; then select TIME
INTERVAL by means of the
▲
F
S
▼▲
S
▼▲
S
▼▲
F
S
▼
▲
F
F
S
▼
▲
F
S
▼
▲
S
▼
▲
S
▼
▲
and keys and confirm with : the display shows the win-
dow for the selection of the TIME INTERVAL.; select the value (in
minutes) with the and keys and then confirm with .
To go back to the main menu press .
During the measurement the instrument takes a sam-
ple of the selected variables every 200ms approx.;
When the selected time (from 1 to 60 min.) expires,
the instrument will calculate the average of the sam-
ples and carry out the data logging. The
historical
data
will therefore be guaranteed to be highly accurate.