Installation Guide

24
Brown Phenolic Boxes
New Work Boxes
1250-UB-S 1050-UB1260
1260-S
1250-UB
2050-UB
2070
2030 1040 20001240
One-Gang Nail On 9.0 – 18.0 Cu. In.
CAT. NO.
SIZE
CU. IN. MOUNTING MEANS DESCRIPTION DIMENSIONS (IN.)
STD. CTN.
QTY.
2050-UB 9.0 Bottom nails 3
9
16 L x 2
1
4 W x 1
13
16 D 100
2070 14.0 Bottom nails 3
9
16 L x 2
1
4 W x 2
5
8 D 100
2030 16.0 Bottom nails 3
9
16 L x 2
15
32 W x 2
13
16 D 100
1040 18.0 Compound angled nails 3
9
16 L x 2
1
8 W x 3
1
8 D 100
1240 18.0 Recessed angled nails 3
11
16 L x 2
1
4 W x 3
5
16 D 100
2000 18.0 Bottom nails “Classic” 3
11
16 L x 2
1
4 W x 3
1
8 D 100
One-Gang Nail On 20.3 – 22.5 Cu. In.
CAT. NO.
SIZE
CU. IN. MOUNTING MEANS DESCRIPTION DIMENSIONS (IN.)
STD. CTN.
QTY.
1250-UB 20.3 Recessed angled nails 3
7
8 L x 2
3
8 W x 3
3
8 D 100
1250-UB-S 20.3 Recessed angled tech screws for wood or steel studs 3
7
8 L x 2
3
8 W x 3
3
8 D 100
1050-UB 21.0 Compound angled nails 3
5
8 L x 2
5
16 W x 3
1
2 D 50
1260 22.5 Recessed angled nails 3
7
8 L x 2
3
8 W x 3
21
32 D50
1260-S 22.5 Recessed angled tech screws for wood or steel studs 3
7
8 L x 2
3
8 W x 3
21
32 D 50
New Fire Rating! Carlon
®
phenolic boxes can be installed in the same
stud cavity of a shared two-hour wall. They may also face opposite
directions with only a 3" horizontal separation — ideal for multi-family
construction!
Carlon
®
Brown Phenolic Boxes
One-Gang Nail On
All Phenolic boxes are listed to UL514C
All Phenolic boxes are listed for masonry walls
All Phenolic boxes are UL Classified for 2 hr. fire wall and/or fire ceiling
All Phenolic boxes meet NEMA OS-2
All Phenolic boxes are permissible for use with 90 degree C conductors
UL File E11461 and R9140