Manual

Bore-Gard
®
Installation - 2x 220 ft.
Cleveland, OH
Pipe Pull Force Data
Maximum 2,395 lbs.
Note: Pull force data generated from self-contained on-board strain gauge and data gathering computer mounted between pipe
lead end and reamer. Data samples taken at a rate of 10 per second.
F
4049.86 15072.8Time (Secs)
-250
2500
Load (lbs)
JOIE1.DAT-TimeHist.Load_cell
Left: The data in the graph above was
generated by our state-of-the-art, self-
contained force-measuring computer, which
is capable of measuring both tensile and
compressive loads. It is protected by a steel
cylinder and mounted on swivels at both
ends. Data was sampled 10 times per
second. This leading-edge technology has
enabled Carlon to determine the actual
loading on the pipe as it is being pulled
through the ground. This is the first known
application of such high technology to the
development and application of pipe for
boring applications.
Pulling Eye
attached to
Bore-Gard
p
ipe
Pull-Force
Measuring
Computer
Reamer
Gross Automation (877) 268-3700 · www.carlonsales.com · sales@grossautomation.com