Conduit & Fittings — Carlon
®
PVC Elbows, Conduit & Fittings
Dimensions — Base Spacers
CAT. NO.
SIZE (IN.) A (IN.) C (IN.) D (DIA.) (IN.) STD. CTN.
S288JHN 2 x 1
1
2 4.25 4.12 2.50 100
S288JJN 2 x 2 4.25 4.62 2.50 100
S288JLN 2 x 3 4.25 5.62 2.50 100
S288LHN 3 x 1
1
2 4.81 5.25 3.63 90
S288LJN 3 x 2 4.81 5.75 3.63 80
S288LLN 3 x 3 4.81 6.75 3.63 60
S288NFN 4 x 1 4.50 5.75 4.63 70
S288NHN 4 x 1
1
2 5.31 6.25 4.63 50
S288NJN 4 x 2 5.31 6.75 4.63 50
S288NLN 4 x 3 5.31 7.75 4.63 60
S288PHN 5 x 1
1
2 5.84 7.31 5.69 50
S288PJN 5 x 2 5.84 7.81 5.69 60
S288PLN 5 x 3 5.84 8.81 5.69 50
S288RHN 6 x 1
1
2 6.38 8.38 6.75 50
S288RJN 6 x 2 6.38 8.88 6.75 50
S288RLN 6 x 3 6.38 9.88 6.75 40
S288SHN 8 x 1
1
2 7.38 10.30 8.75 30
S288SJN 8 x 2 7.38 10.76 8.75 30
Dimensions — Intermediate Spacers
CAT. NO.
SIZE (IN.) A (IN.) C (IN.) D (DIA.) (IN.) STD. CTN.
S289JHN 2 x 1
1
2 3.88 4.12 2.50 120
S289JJN 2 x 2 4.38 4.62 2.50 100
S289JLN 2 x 3 5.38 5.62 2.50 80
S289LHN 3 x 1
1
2 5.01 5.25 3.63 100
S289LJN 3 x 2 5.51 5.75 3.63 80
S289LLN 3 x 3 6.51 6.75 3.63 60
S289NFN 4 x 1 5.51 5.73 4.63 70
S289NHN 4 x 1
1
2 6.01 6.25 4.63 60
S289NJN 4 x 2 6.51 6.75 4.63 60
S289NLN 4 x 3 7.51 7.75 4.63 50
S289PHN 5 x 1
1
2 7.07 7.31 5.69 50
S289PJN 5 x 2 7.57 7.81 5.69 50
S289PLN 5 x 3 8.57 8.81 5.69 30
S289RHN 6 x 1
1
2 8.14 8.38 6.75 50
S289RJN 6 x 2 8.64 8.88 6.75 40
S289RLN 6 x 3 9.64 9.88 6.75 30
S289SHN 8 x 1
1
2 10.14 10.30 8.75 30
S289SJN 8 x 2 10.64 10.76 8.75 30
Accessories
* First number indicates trade size of duct, second number indicates separation between conduits or ducts.
Snap-Loc
®
Reducer
CAT. NO.
SIZE
(IN.)
STD.
CTN.
S287F 1 100
S287J 2 100
Beaded Strap
CAT. NO.
STD. CTN.
S28612 1 Bag of 250
Rebar Holder
CAT. NO.
STD. CTN.
S258RH 100
15" in length
Specifications
B
C
A
3" Standard for all Base Spacers
(with the exception of the 4X1-S288NFN)
Suggested Specification:
(Duct) (Conduit) bank shall be encased in concrete with at least three
inches of concrete at the top and bottom and two inches on each side.
A horizontal and vertical separation between the ducts of ____* inches
shall be maintained by installing Carlon
®
high-impact spacers with
horizontal and vertical locking intervals of ____** feet.
*Standard Separations of 1", 1
1
2", 2" and 3" are available.
**Preferred interval between spacer assemblies is 8 to 10 feet.
Hole Dia. = .688 min.
.750 max.
Carlon
®
Snap-Loc
®
Spacers (continued)
Spacers