2.9.1. Test Cable Set
The bench-testing cable set (“RC-TECH-KIT”) will allow you to
bench test a Basestation with two CPEs. Connect the units with
the supplied cables and connectors. This consists of a set of
coax jumper cables (one for each unit), an F-type splitter and
five 19 dB attenuators (one for the Basestation, two for each
CPE).
2.9.2. Setting up the Bench
Use the supplied yellow Ethernet patch cable to connect the
radio’s Ethernet port to the Base controller board Ethernet port
as shown in Figure 4.
For Internet
access, connect the Basestation unit to a DHCP-
enabled network via a standard Ethernet cable. Plug the
Ethernet cable into the Ethernet port nearest to the power jack.
Note the blue cable in Figure 5 as an example:
Connect the
Basestation unit’s power supply to its barrel-type
power jack, as shown in
photo.
Figure 3: Bench-Testing Cable Set
Usi
ng a standard Ethernet
cable (not supplied),
connect each CPE unit to
the “Out” connection of a
POE injector as shown
below:
Connect each unit to a
ximately 3-5 minutes for the system to
initialize.
power source.
Wait appro
Figure 4: Basestation with Ethernet cable connected
Figure 5: Basestation Connections