User's Manual

Trailblazer Installation and User Manual version 1.02 36
Telephone Line Gas Discharge Lightning Surge Protector Specifications
CWT Part number 640-6500
Description Sealed gas tube station protector
DC Breakdown@100V/s 300-500V
Impulse Breakdown
100V/µs
10kV/µs
100V/µs, vented
600V
850V
1200V
Insulation Resistance@100V/leakage current 10e10
Capacitance@1kHz <15pF
DC Extinguishing (Network applied) @52V, 135V, 150V
<150ms
Impulse Life Characteristics
>400x500A 10/1000µs
10kA 8/20µs
AC Life characteristics >65A, 11 cycles
Enclosure Material Weather and UV resistant , high impact, flame retardant plastic.
Dimensions 5.7”H x 3.4”W x 2.2”D
Table 13: Subscriber side protection