Operator`s manual

During operation, working hours can always be displayed by switching for a BRIEF
INTERVAL key (+) or (-). The display shows now the ref. indicator “b” on page 7
and working hours are displayed for 3 seconds. During this interval the EVS solenoid
valve is energized or de-energized by the monitor (according to what programmed in
“type” parameter) only if the “auto-feed” function has been enabled (see chapter 5.3),
whereas the EVR solenoid valve is never energized.
5. Range of parameters displayed
Description Range
Engine RPMe 0 ÷ 9990 steps of 10 RPMs
Working
hours
0.0 ÷ 999.9 hours, steps of 0.1 hour ( 6 minutes ); once 999.9 are
reached, then steps of 1 hour until 9999 hours.
Working hours increase only if RPMs > 500.
6. Setting
The device has two setting phases: “user” setting and "manufacturer" setting. Both
programming phases can be carried out with the engine operating (RPMs > 500). The
operator shall complete the procedure for each phase by confirming all parameters at
a time to allow all modified parameters are stored. Otherwise, if the operator is within
one programming phase and no key is selected for an interval of 7 seconds, the
monitor quits the phase WITHOUT storing any executed changes.
The “user” phase permits programming of the following parameters:
Minimum value for RPMs
Maximum value for RPMs
Machine type selection (with or without reverse)
Reverse time (not used if the reverse valve is not present).
The “manufacturer” setting allows programming of the following parameter:
Pulses/revolution for engine RPMs counting (Set By Factory)
NOTES: the parameter value is kept displayed during each programming phase; the
parameter name is displayed only while going from one parameter to the next one or
when keys + (plus) and (-) minus are simultaneously pressed.
For safety purposes, the EVS solenoid valve is energized or de-energized (according
to what programmed in “type” parameter) by the monitor each time a programming
phase is entered only if the “auto-feed” function has been enabled (see par. 5.3),
whereas the EVR solenoid valve is never energized.