Battery Charge Profile Chart 
Auto Equalize: The GP-PWM-30 has an automatic equalize feature that 
will charge and recondition your batteries once a month at a higher 
voltage to ensure that any excess sulfation is removed. This feature is 
recommended for Flooded batteries only. Check with your battery 
manufacturer.  
IMPORTANT: This feature is only available for wet cell or flooded 
batteries (Charging Profile 1). 
Battery Type 
FLOODED  AGM  GEL 
Charging Profile #  1  2  3 
Float Charge @ 25°C: 
13.7V (+/- 0.1V) 
Bulk/Absorption Charge @ 25°C: 
Applied for 1h each morning 
14.4V (+/- 0.1V) 
14.1V 
(+/- 0.1V) 
Boost Charge 
Applied for 2 hours if the battery voltage drops 
below 12.3 volts.  
14.4V (+/- 0.7V) 
14.1V 
(+/- 0.1V) 
Equalization Charge 
Applied for 2 hours every 28 days and if the 
battery voltage drops below 12.1 volts. 
14.8V 
(+/-0.1V) 
N/A  N/A 
The Boost Charge will occur in addition to the Bulk Charge. The Equalization Charge will 
occur in addition to the Boost Charge. 
If a charging cycle is unable to complete in a single day, it will continue the following day. 
The terms FLOODED, AGM and GEL are generic battery designations. Choose the 