Specifications

Chapter 1 Installation
1-1
INSTALLATION
CAUTION:
Never install telephone wiring during a lightning storm.
Never install telephone jacks in wet locations unless the jack is specifically designed for wet locations.
Never touch uninsulated telephone wires or terminals unless the telephone line has been
disconnected at the network interface.
Use caution when installing or modifying telephone lines.
UNPACKING
This product is shipped as a complete package which contains the Access BankTM channel bank, 115Vac
to -48Vdc power converter cube, and accessories.
Check the materials in the box against the Table 2.1 Shipping Material List. Inspect the unit for any
signs of damage. Report any damages to the shipper. Retain all packaging material in the event that you
need to move or ship the unit in the future.
Table 2.1 Shipping Material List
Description Model Quantity
Access Bank
TM
channel bank AB-12 or AB-24 1
19" wall-mount adapters (4) mounted on the
Access Bank
AB-WMA 4
Access Bank -48Vdc/1A output, 115 Vac input
power converter cube with 16 AWG- 5' wall plug
power cord and 8' dc connector cord.
AB-115POWER 1
Modular T1 Network Cable, RJ48C to RJ48C, 10
feet with RFI Choke.
P01575-10 1
Access Bank Warranty Card AB-WC 1
Access Bank User's Manual AB-MANUAL 1
SITE SELECTION
The installation site should provide proper room for adequate ventilation and cable routing. For
horizontal (rack mounted) installation, allow at least 5 inches at the back of the Access Bank control panel
for cables and air flow. At least 18 inches of clearance from the removable rear panel of the Access Bank
is necessary for maintenance. Above and below unit allow 1.75 inches clearance for air flow.