Network Device Installation and User's Guide

3-2 9/24/01
3.2 Dual T1 Network Line Interfaces
3.2.1 Total Bandwidth
3.072 Mbps
3.2.2 DS-1 Output Signals
Pulse amplitude: 2.0 V to 3.6 V ±60 Hz variations
Line Rate: 1.544 Mbps ±50 bps
Format: T1 type bipolar (except where intentional BPVs are introduced by B8ZS line
coding)
3.3 Line Codes
AMI or B8ZS and line code conversions between T1 lines
3.4 Framing
D4 (Superframe) or ESF and framing format conversions between T1 lines
3.5 Clock Source
Loop Timing: Selectively recovered from incoming T1 Span 1 or Span 2
Master Clock: Internal Enhanced Stratum 4E Crystal Oscillator ±32 ppm accuracy)
3.6 T1-to-T1 Delay
Latency: 3 frames maximum (0.375 ms)
3.7 T1 Channel Service Units (CSUs)
Integrated intelligent CSUs support all standard diagnostic functions and DS-1 or DSX-1
signal levels from 0 to -30 dB
Software programmable Line Build Out (LBO): 0 dB/DSX (0’-133’) (default), -7.5 dB, -
15 dB, -22.5 dB, DSX (133’-266’), DSX (266’-399’), DSX (399’-533’), DSX (533’-
655’)
AT&T 54016 Maintenance Messages or T1.403 Performance Report Messages (PRMs)
through 4 Kbps ESF Facility Data Link (FDL)