Network Device Installation and User's Guide
3-6 9/24/01
• Bellcore TR-NWT-000499 Generic Transport Requirements
• FCC Part 15, Class A for Radiated Emissions Control
• FCC Part 68, CS-03 for T1 CSU Interface, Network Protection, Line Balance, REN
• National Electrical Code 1996 Safety Requirements
• NRTL Safety Listed: UL 1459, 2nd Edition concerning Minimum 600 Vrms Lightning
Protection, CSA
• IEEE 802.3 10baseT interface
• EIA RS-232-D
• RFC 1213, 1573, 1406, 1659
3.17 Power
• Control Panel DC Power Input Terminal: -48 Vdc with 1 Amp circuit breaker from local
battery
• Standard Power Source: 115 Vac to -48 Vdc Power Converter Cube
• Optional Power Source: 220 Vac to -48 Vdc Power Converter Cube
• Input voltage: -42 to -60 Vdc at 1 Amp (constant current power source)
3.18 Environmental
• Altitude: 0 to 10,000’ (0 to 3,048 m)
• Humidity: 0 to 95%
• Temperature Range: 32
º
to 104
º
F (0
º
to 40
º
C)
• Thermal Protection: Automatic cut-off at 104
º
F (40
º
C) until lowered below limit
3.18.1 Physical Dimensions
• Height: 1.75 inches (4.45 cm)
• Depth: 17.75 inches (45.1 cm)
• Width: 17 inches (43.2 cm)
• Weight: 14.5 Lbs (6.6 Kg) fully loaded