Configuration
CPU Redundancy
Release CPU Control
If desired, the online CPU can be made to release control (switch) to the standby
CPU by performing the following steps. The online CPU will then become the
standby CPU, and vice versa. This command may be used during maintenance
procedures.
Reboot Standby CPU
If desired, the standby CPU can be rebooted by performing the following steps.
This command may be used during maintenance procedures.
Install Single or Dual CPU
This configuration item only activates detection of the SNMP trap Standby CPU
missing. If only one CPU is present, select Single CPU. If two CPUs are
installed, select Dual CPU.
Select Maintenance/Diags
Select Redundancy
Select CPU
Select Release CPU Control
Select Maintenance/Diags
Select Redundancy
Select CPU
Select Reboot Standby
Select Maintenance/Diags
Select Redundancy
Select CPU
Select Installed