Operating instructions

7-22 Commissioning and Parameterization Rexroth IndraDrive
DOK-INDRV*-FU*********-IB01-EN-P
Error memory (P-0-0192) with indication of time during which error is
present (P-0-0193)
Press
key.
Diagnostic message memory (S-0-0375) with indication of time
during which diagnostic message is present (P-0-0105)
Press
key.
Operating hours:
Control section (P-0-0190)
Power section (P-0-0191)
The operating hours are displayed as seconds.
Current configuration of the drive controller:
Firmware
display of firmware version (S-0-0030)
Motor type
type designation of motor (S-0-0141)
Press
key.
Control section
type designation of control section (P-0-1520)
Power section
type designation of power section (S-0-0140)
Motor Potentiometer
To use the motor potentiometer you must have selected and
parameterized "Motor potentiometer" as velocity command value (see
description of "Guided Parameterization").
Starting point: main screen
By pressing key
several times you get to main screen. By means of
Esc key, you might possibly have to exit editing mode before.
Press key
.
Mode selection is displayed.
Select Motor potentiometer.
Press key
.
Motor potentiometer display appears:
Fig. 7-14: Motor potentiometer
Reduce velocity of motor:
Press
Mon key and keep it pressed.
Increase velocity of motor:
Press Prog
+
key and keep it pressed.
Exit motor potentiometer:
Press Esc key.
History, Error Memory
Current Configuration
Requirements
Motor Potentiometer Operation