Operating instructions

Rexroth IndraDrive Electrical Data 5-15
DOK-INDRV*-FU*********-IB01-EN-P
5.3 Additional Components
Mains Filter HNF
HNF01.1A- … -A-480-NNNN
Unit
F240-E0051
M900-E0051
F240-E0125
M900-E0125
F240-E0202
M900-E0202
F240-R0026
M900-R0026
F240-R0065
M900-R0065
F240-R0094
M900-R0094
Power dissipation W < 89 < 91 < 127 < 174 < 238 < 373 < 73 < 77 < 163 < 157 < 135 < 146
Phase current (continuous
current)
A 51 51 125 125 202 202 26 26 65 65 94 94
Phase current (peak
current
1)
)
A 77 77 188 188 303 303 65 65 163 163 235 235
Leakage current at filters
input (line side)
A < 2 < 2 < 2,2 < 2,2 < 2,5 < 2,5 < 2 < 2 < 2 < 2 < 2,2 < 2,2
Leakage current at filters
output (load side)
A < 2 < 2 < 2,2 < 2,2 < 2,5 < 2,5 < 2 < 2 < 2 < 2 < 2,2 < 2,2
allowed THD (Total Harmonic
Distortion)
% see Project Planning Manual "Rexroth IndraDrive Drive System"
Reduction of allowed
operating data due to
harmonic content
- see Project Planning Manual "Rexroth IndraDrive Drive System"
Input supply voltage V 3 x AC 380…480V ±10%, 50/60Hz ±2%
Sum of leakage currents at
filters input with power supply
unit switched off:
1 phase failed
2 phases failed
A
< 0,83
< 1,4
Leakage resistance (Phase –
Ground)
MOhm > 15
Protection category - IP20
Materials - free of asbestos and silicone
Terminal L1, L2, L3 resp. L1.1, L2.1, L3.1:
Cross section flexible min. mm
2
0,5 0,5 16 16 50 50 0,5 0,5 10 10 16 16
Cross section flexible max. mm
2
16 16 50 50 150 150 10 10 25 25 50 50
Cross section rigid min. mm
2
0,5 0,5 16 16 35 35 0,5 0,5 6 6 16 16
Cross section rigid max. mm
2
25 25 50 50 150 150 16 16 35 35 50 50
Cross section AWG min. -- 20 20 6 6 2 2 20 20 10 10 6 6
Cross section AWG max. -- 4 4 0 0 00/3 00/3 6 6 2 2 0 0
Tightening torque Nm
4,8
±0,5
4,8
±0,5
< 25 < 25 < 25 < 25
4,8
±0,5
4,8
±0,5
4,8
±0,5
4,8
±0,5
< 25 < 25
1) duration: 300 ms ;
cycle duration:
for feeding units: 0,67 s;
for regenerating units: 1,42 s;
base load: 60% (continuous current)
Fig. 5-24: Data HNF