51AKB / 51 AKC OWNER’S MANUAL
This manual applies to the following models 009 012 009 012 Page Control panel .................................................... 1 Accessories supplied ....................................... 1 General information ......................................... 2 Correct use .................................................... 2/3 Preparing to use ............................................... 4 Cooling with dehumidification ......................... 5 Dehumidification ......................................
General information • Check that the power supply at the installation site is 230 V (min. 198 V - max. 264 V). • The unit installation must comply with all applicable local and national regulations. • It is recommended to install a circuit breaker or a 16 A safety fuse upstream of the supply switch. • The appliance must always be earthed. • If an extension lead is needed (up to 25 m) make sure that the wire section is not less than 1.5 mm2.
Correct use ENGLISH 5 MIN. Always disconnect the cable from the power socket before moving or cleaning the unit. Never use the plug to switch the unit on or off. When switching off or moving the unit to another place wait at least 5 minutes before restarting the air conditioner. 10° 60° Adjusting the air flow direction The air conditioner has a guide vane at the top that can be adjusted to any angle between 10° (partially closed) and 60° (fully open).
Preparing to use 2 1 Place the outdoor unit outside, ensuring that air can circulate freely around and through the unit. Outdoor section may be placed on the ground or a balcony or hung from a window sill using the straps and bracket provided. 3 For window sill installation use the supplied bracket and screws. Fix the bracket to the window sill as shown. 4 5 Secure the casing to the bracket with the spring-clips at the end of the straps. Adjust the length of the straps so that the casing is level.
Cooling with dehumidification ENGLISH 1 2 Place the outdoor unit outside, ensuring that air can circulate freely around and through the unit. Place the flexible tube between two shutters set ajar. Hold the hose end in position with the fastening strap and suction cup. 4 3 Open the air flow direction guide vane. Plug the unit in. 6 7 5 The appliance is now ready for cooling. The unit has two fresh air outlets, so that the desired room temperature is reached quickly.
Dehumidification 2 1 TURBO SILENT The dehumidification only function should be used if you want to remove moisture from the room air without lowering the temperature. Place the unit in the space to be dehumidified (room, garage, cellar or storeroom). Plug the unit in. Open the air flow direction guide vane. Turn the mode selector to the dehumidification symbol. 4 3 5 TURBO SILENT The dehumidification indicator light on the control panel is illuminated.
Fan only ENGLISH 2 1 3 TURBO SILENT If the air conditioner is to be used in the fan only mode (ventilation) the outdoor unit can be placed either outside or inside the room. Plug the unit in. Open the air flow direction guide vane. Turn the mode selector to the high or low fan speed symbol. 5 4 The unit will now operate in the fan only mode.
In case of… If the unit appears not to be operating correctly, before calling a service technician please check that... ... the operating instructions in the literature have been followed. ... the main switch is switched on, that the power supply is not interrupted and that the unit is correctly plugged in. ... the filters are not dirty. ... the water collection tank is correctly inserted in its position.
L010121H12 - 0398 Via R. Sanzio, 9 - 20058 Villasanta (MI) Italy - Tel. 039/3636.1 The manufacturer reserves the right to change any product specifications without notice. Order No. 15157-74M8, March 1998. Supersedes Order No. 15157-74, February 1997.