UFM®-SDN Appliance Hardware User Manual P/N: MUA9002F-2SF-250, MUA9002F-2SF-500, MUA9002F-2SF-1K, MUA9002F-2SF-2K, MUA9002F-2SF-4K, MUA9002F-2SF-HA Rev 1.5 www.mellanox.
Rev 1.5 NOTE: THIS HARDWARE, SOFTWARE OR TEST SUITE PRODUCT (“PRODUCT(S)”) AND ITS RELATED DOCUMENTATION ARE PROVIDED BY MELLANOX TECHNOLOGIES “AS-IS” WITH ALL FAULTS OF ANY KIND AND SOLELY FOR THE PURPOSE OF AIDING THE CUSTOMER IN TESTING APPLICATIONS THAT USE THE PRODUCTS IN DESIGNATED SOLUTIONS. THE CUSTOMER'S MANUFACTURING TEST ENVIRONMENT HAS NOT MET THE STANDARDS SET BY MELLANOX TECHNOLOGIES TO FULLY QUALIFY THE PRODUCTO(S) AND/OR THE SYSTEM USING IT.
UFM-SDN Appliance Rev 1.5 Table of Contents Table of Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 List of Figures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 List of Tables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Revision History . . . . . . . . . . . . . . . . .
Rev 1.5 4.10 4.11 4.12 4.13 Appliance Shut Down Procedure. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Disassembly of the Appliance from the Rack . . . . . . . . . . . . . . . . . . . . . . . . . . . Remove the Battery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 32 32 32 Chapter 5 Troubleshooting . . . . .
UFM-SDN Appliance Rev 1.5 List of Figures Figure 1: Pull Out Tab Location on Appliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Figure 2: Pull Out Tab Example . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Figure 3: UFM-SDN Appliance Front and Rear Side Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Figure 4: System Status Indicators . . . . . . . . . . . . . . . . . . . . . . .
Rev 1.5 List of Tables Table 1: Revision History Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Table 2: Reference Documents and Web Sites . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Table 3: Abbreviations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Table 4: Figure 4 Legend . . . . . . . . . . . . . . . . . . . . . . . .
UFM-SDN Appliance Rev 1.5 Revision History Table 1 - Revision History Table Date Revision Description August 2013 1.5 Added Regulatory label in Traditional Chinese Changed Input parameters July 2013 1.4 Added Safety Warnings in traditional Chinese See Section Appendix H: May 2013 1.3 Reformatted TroubleShooting Section 5. April 2013 1.2 Added figure #26 Added warning not to remove a good HDD See Section 4.7 renamed figure 1 and figure 2 March 2013 1.
Rev 1.5 About this Manual This manual describes the installation and basic use of the UFM®-SDN Appliance (Unified Fabric Manager for Software Defined Networks Appliance). Intended Audience This manual is intended for software and hardware engineers, users and system administrators responsible for fabrics management. The manual assumes familiarity with the InfiniBand® Architecture Specification and with the Ethernet specification.
UFM-SDN Appliance Rev 1.5 Conventions Throughout this manual, the name and the terms UFM-SDN Appliance and appliance are used to describe the UFM-SDN appliance, unless explicitly indicated otherwise. The following icons are used throughout this document to indicate information that is important to the user. This icon makes recommendations to the user. This icon indicates information that is helpful to the user. This icon indicates a situation that can potentially cause damage to hardware or software.
Rev 1.5 Mellanox Product Legend The following table identifies the components of the appliance as they correspond to the OPN MUA9002F-2SF-250. Place Field M Decoder Mellanox Technologies UA System Type UFM-SDN Appliance 9 Data Transfer Protocol 9 = VPI 00 Size of box 00 = 1U 2 Number of HCA ports 2 = 2 QSFP ports F Type of HCA cards CX354A ConnectX-3 dual port FDR - Separator 2 # Power Supplies 0=0, 1=1, 2=2....
UFM-SDN Appliance 1 Rev 1.5 Overview Mellanox's Unified Fabric Manager (UFM®) is a powerful platform for managing scale-out computing environments. UFM® enables data center operators to efficiently monitor and operate the entire fabric, and maximize fabric resource utilization. UFM® eliminates the complexity of fabric management, provides deep visibility into fabric traffic and health, and optimizes application performance.
Rev 1.5 Basic Operation and Installation 2 Basic Operation and Installation 2.1 UFM-SDN® Appliance Hardware Overview Figure 3 shows the power side panel and connector side panel views of the appliance. The figure shows interfaces, the hot-swap power supply location, hot swap HDD drawers, 6 – RJ-45 connectors, 5 – USB connectors, and various status LEDs.
UFM-SDN Appliance Rev 1.5 Table 4 - Figure 4 Legend Label Description Label Description A System ID Button w/Integrated LED F Power Button w/Integrated LED B NIC-1 Activity LED G NIC-2 Activity LED C NIC-3 Activity LED H NIC-4 Activity LED D System Cold Reset Button I Hard Drive Activity LED E System Status LED 2.1.1.1 Appliance Status LED This is a two color LED Green/ Amber each side of the appliance. .
Rev 1.5 Basic Operation and Installation 2.1.1.2 Power LEDs Figure 5: UFM-SDN® Appliance Front and Rear Side Panels Front side Mellanox TECHNOLOGIES UFM-SDM ID ID Mellanox Mellanox Mellanox 2 4 1 3 Mellanox Rear side Power supply Module #2 Power supply Module #1 Figure 6: System Power and On/Off Button and Indicator ID ID 2 4 1 3 Power Button w/Integrated LED The primary power supply unit (PS1) is located on the left side of the power side panel, with PS2 on the right of the PS1.
UFM-SDN Appliance Rev 1.5 Figure 6 shows the On/Off switch which contains an integral LED to show the power status of the appliance.
Rev 1.5 Basic Operation and Installation 2.1.1.4 3.5 Inch Hard Drive LEDs Figure 9: Hard drive LEDs Amber Status LED Green Activity LED Status LED Activity LED Off No access and no fault Solid On Hard drive fault has occurred Blinking Raid is rebuilding (this happens after replacing a faulty drive) Off Power on and Drive spun down Solid On Power on with no drive activity Blinking Power on with drive activity or drive spinning up 2.1.1.
UFM-SDN Appliance 2.1.2 Rev 1.5 Reset Button Figure 10: Cold Reset Button ID ID 2 4 1 3 System cold reset button This appliance has a system cold reset button. Pressing this button performs a forced reset of the appliance hardware. In general, for a graceful shutdown of the system (stopping all services, closing all files, flushing all caches etc.) use the CLI. 2.1.3 NIC Activity LED Indicators The number LEDs display NIC activity.
Rev 1.5 2.2 Interfaces Air Flow This appliance comes with one air flow pattern. That is front (hard-drives) side to back (powersupplies) side.
UFM-SDN Appliance 3.1 Rev 1.5 On/Off Button This switch is found on the front side of the appliance. See Figure 6. This button can turn the appliance on and off. In general, for a graceful shutdown of the system use the CLI. To do a forced shut down of the appliance, press and hold the button down until the appliance turns off. The led within the button displays the power on status. 3.2 RJ-45 Serial Port This RJ-45 port is found on the rear side of the appliance. See Figure 13.
Rev 1.5 3.4.1 Interfaces QSFP Port Interfaces There are two I/O LEDs per port in dual-port designs. See Table 8 for LED functionality in InfiniBand mode.
UFM-SDN Appliance Rev 1.5 NIC#1 Ethernet connector gets connected to Ethernet switches. This switch must be configured to 100M/1G auto-negotiation. 3.6 USB interface The USB interface can be used to update the UFM. There are five USB connectors. The USB is used for various actions: • UFM configuration fetch/upload • UFM db fetch/upload • UFM counters.csv upload • UFM license install • UFM monitoring history backup The USB is used in conjunction with the CLI for these operations.
Rev 1.5 Interfaces 1. Installation Instructions Read all installation instructions before connecting the equipment to the power source. 2. Over-temperature This equipment should not be operated in an area with an ambient temperature exceeding the maximum recommended: 40°C (103°F). Moreover, to guarantee proper air flow, allow at least 8cm (3 inches) of clearance around the ventilation openings. 3. Stacking the Chassis The chassis should not be stacked on any other equipment.
UFM-SDN Appliance Rev 1.5 9. Equipment Disposal Disposal of this equipment should be in accordance to all national laws and regulations. 10. Local and National Electrical Codes This equipment should be installed in compliance with local and national electrical codes. 11. Battery Replacement There is a risk of explosion should the battery be replaced with a battery of an incorrect type. Dispose of used batteries according to the instructions. 12.
Rev 1.5 4 Mechanical Installation Mechanical Installation The UFM®-SDN Appliance can be rack mounted and is designed for installation in a standard 19” rack. The power (rear) side of the appliance includes 2 hot-swap power supply modules. The UFM-SDN Appliance accepts input voltages of 100 - 127 VAC and 200 - 240 VAC for all possible PS units. The installer should use a rack capable of supporting the mechanical and environmental characteristics of a fully populated rack.
UFM-SDN Appliance Rev 1.5 Figure 16: Left-hand Rail Outside View Extended L L Figure 17: Left-hand Rail Inside View 3. Slide the appliance into the rails as shown in the diagrams on the installation guide packed in the box. Figure 18: Insert Appliance Into Rails 4. Ground the appliance. 5. Plug in the power cables. 6. Push the ON/OFF button to start. Figure 19: Turn On ID ID 2 4 1 3 Power Button w/Integrated LED 7.
Rev 1.5 Mechanical Installation Any amber status LEDs are cause for concern and must be dealt with immediately. It can take up to 5 minutes to boot up, during which time the status LED may indicate red. 4.2 Connecting UFM-SDN Appliance to your Network/Fabric Unified Fabric Manager (UFM®) requires both InfiniBand and Ethernet (out-of band management) connectivity where eth0 should be connected to a management network switch and both InfiniBand ports should be connected to InfiniBand switches.
UFM-SDN Appliance Rev 1.5 grounded and that there is a valid ground connection between the chassis of the appliance and the rack. Test the ground using an Ohm meter. Some national and/or local codes may require IT components to be bonded and externally grounded (not including the power cord ground). You must follow all national and local codes when installing this equipment. 4.4 Power Connections and Initial Power On The UFM-SDN Appliance ships two power supply units.
Rev 1.5 Mechanical Installation Figure 22: Remove the PSU Handle 2. If a power supply is installed, grab the handle with your thumb pointing toward the latch. Push the latch with your thumb towards the handle while you pull the power supply out of the appliance. Figure 23: Insert the PSU 3. Insert the power supply module into the power supply cage and push all the way until it clicks into place. Do not run the appliance with openings due to missing parts.
UFM-SDN Appliance Rev 1.5 RAID Failure Notification In case one of the drives fails, the state of the RAID volume becomes “Degraded”, the system provides the following notification: 1. An amber light appears on the HDD drawer. 2. The user will receive an email notification that the RAID state has changed to “Degraded”. 3. The user will also receive a notification when he logs into the CLI.
Rev 1.5 4.7 Mechanical Installation Removing a Hard Disk Drive from a 3.5” Hard Drive Carrier Figure 25: Remove HD Latch Never pull out a working hard drive while the appliance is turned on. You can safely pull out a faulty hard drive indicated by a solid amber light. If one HDD physically fails, the appliance keeps working thanks to RAID mirroring.
UFM-SDN Appliance Rev 1.5 Figure 26: Proper Insertion Push the HDD into the appliance from here until the handle moves toward the appliance. Inserted properly Now, Push to latch 5. Close the latch. The software RAID mechanism will identify that a new HDD was inserted and synchronize the data with the second HDD, this process might take up to 48 hours to complete. 4.8 Battery Replacement Mellanox Technologies does not support battery replacement.
Rev 1.5 4.11 Mechanical Installation Disassembly of the Appliance from the Rack To disassemble the appliance from the rack: 1. Shut down the appliance. 2. Unplug and remove all connectors. 3. Unplug all power cords. 4. Remove the ground wire. 5. Unscrew the 2 center bolts from inside the handles. 6. Slide the appliance from the rack. 7. Remove the rail slides from the rack. 4.
UFM-SDN Appliance 5 Rev 1.5 Troubleshooting As soon as the appliance is plugged in make sure that the green power LEDs on the PS units are on. See “Basic Operation and Installation” on page 12 for the names and locations of the various LEDs. Table 9 - TroubleShooting Issues and Resolutions # Issue Resolution 1 System Status LED is RED Unplug the appliance and call your Mellanox representative. 2 Power Supply Unit Status 1. Check that the power cable is plugged into a working outlet. 2.
Rev 1.5 Appendix A: UFM-SDN Appliance Specifications Table 10 - UFM-SDN Appliance Specification Data Physical Size Weight Mounting (1U)1.7”H x 17.2”W x 27.9”D 43.2mm 438 mm 709.37 mm 14.1 kg 2 PS units 19” Rack mount SerDes Speeds / 10, 20, 40, or 56 Gb/s per port Air Flow/ Heat dissipation Air Flow: Maximum Heat dissipation: 62 CFM 750 Watt Max – 2560 BTU/hour Power and Environmental Input Voltage: Input Voltage / 750W power supply module CPU • 100 - 127 V at 50/60 Hz 7 A • 200 - 240 V at 50/60 Hz 3.
UFM-SDN Appliance Rev 1.
Rev 1.
UFM-SDN Appliance Rev 1.5 Appendix C: Avertissements de sécurité pour l'installation(French) 1. Instructions d'installation Veuillez lire la totalité des instructions d'installation avant de relier l'équipement au secteur. 2. Blessures à cause du poids Prévoyez assez de personnel pour soulever ce produit en toute sécurité. <40 lbs <18 kgs 3.
Rev 1.5 7. Châssis empilé sur d'autres équipements Le châssis ne doit pas être empilé sur d'autres équipements. S'il tombe, il peut endommager l'équipement ou entraîner des blessures. 8. Connexion de l'alimentation redondante : danger d'électrocution Ce produit est équipé d'une alimentation redondante ou d'un cache si elle est absente. Dans ce dernier cas, ne pas faire fonctionner le produit si le cache est retiré ou mal fixé. 9. Fusibles phase/neutre Ce système dispose de fusibles phase/neutre.
UFM-SDN Appliance Rev 1.5 15. Mise au rebut de l'équipement La mise au rebut de cet équipement doit se faire conformément à toutes les lois et réglementations nationales. 16. Codes électriques locaux et nationaux Cet équipement doit être installé conformément aux codes électriques locaux et nationaux. 17. Codes d'installation Cet appareil doit être installé conformément à la version la plus récente des codes électrique nationaux.
Rev 1.5 21. Information d'ajout de branchement à la terre (GND) Avant de relier cet appareil au secteur, ses vis des bornes de la terre de protection doivent être reliées à la terre de l'installation électrique de l'immeuble. (Informations de branchement à la terre) : L'installation électrique doit fournir une connexion à la terre, et un technicien de maintenance doit y relier l'équipement de façon permanente.
UFM-SDN Appliance Rev 1.5 26. Ne pas utiliser comme étagère ou plan de travail Attention : un équipement coulissant ou monté sur rail ne doit pas servir d'étagère ni de plan de travail. Les rails ne sont pas destinés à faire coulisser l'unité hors du rack. Ils sont destinés à une installation permanente à l'emplacement final, pas pour l'entretien ni la maintenance. 27.
Rev 1.5 Appendix D: Installation – Sicherheitshinweise(German) 1. Installationsanleitungen Lesen Sie alle Installationsanleitungen, bevor Sie das Gerät an die Stromversorgung anschließen. 2. Verletzungsgefahr wegen des Gewichts Um das Produkt sicher anzuheben, genügend Personen einsetzen. <40 lbs <18 kgs 40 - 70 lbs 18 - 32 kgs 70 - 121 lbs 32 - 55 kgs >121 lbs >55 kgs 3.
UFM-SDN Appliance Rev 1.5 7. Stapeln des Chassis Das Chassis sollte nicht auf andere Geräte gestapelt werden. Wenn das Chassis herunterfällt, kann es zu Verletzungen und Beschädigungen an Geräten führen. 8. Redundanter Stromversorgungsanschluss - Elektrische Gefahr 9. Zweipolig/Neutrale Sicherung Achtung: Zweipolige bzw. Neutralleiter-Sicherung im Netzteil. Netzstecker ziehen, um sicherzustellen, daß keine Spannung am Gerät anliegt.
Rev 1.5 16. Regionale und nationale elektrische Bestimmungen Dieses Gerät sollte unter Beachtung der regionalen und nationalen elektrischen Bestimmungen installiert werden. 17. Installationscodes Dieses Gerät muss entsprechend der aktuellsten Version des National Electrical Code installiert weden. In Nodamerika muss das Gerät gemäß den geltenden Anforderungen des US National Electrical Code und des Canadian Electrical Code installiert werden. 18.
UFM-SDN Appliance Rev 1.5 23. Verbindung der Geräte untereinander Kabel für den Anschluss an das Gerät RS232-und Ethernet-Schnittstellen müssen UL zertifiziert Typ DP-1 oder DP-2. (Hinweis-, wenn nicht mit Wohnsitz in LPS-Schaltung) Überstromschutz: Eine leicht zugängliche Auflistung Abzweigleitung ÜberstromSchutzeinrichtung 20 A bewertet werden müssen in dem Gebäude Verkabelung. 24.
Rev 1.5 Appendix E: Advertencias de seguridad de instalación(Spanish) 1. Instrucciones de instalación Antes de conectar el equipo a la fuente de alimentación, leer todas las instrucciones de instalación. 2. Lesión corporal a causa de peso .Recurra a suficientes personas para levantar este producto sin <40 lbs <18 kgs 40 - 70 lbs 18 - 32 kgs 70 - 121 lbs 32 - 55 kgs >121 lbs >55 kgs 3.
UFM-SDN Appliance Rev 1.5 7. Apilamiento del chasis Los chasis no se deben apilar sobre otros equipos. La caída del chasis podría causar lesiones corporales, así como daños al equipo. 8. Conexión redundante de fuente de alimentación: peligro de descarga Este producto incluye una fuente de alimentación redundante o, en su lugar, una vacía. Si se dispone de una fuente de alimentación vacía, no utilizar el producto si su tapa está quitada o no está bien cerrada. 9.
Rev 1.5 15. Eliminación del equipo La eliminación definitiva de este equipo se debe efectuar conforme a todas las leyes y reglamentaciones nacionales. 16. Códigos eléctricos locales y nacionales Este equipo se debe instalar conforme a los códigos eléctricos locales y nacionales. 17. Códigos de instalación Este dispositivo se debe instalar conforme a la versión más reciente de los códigos eléctricos nacionales del país en cuestión.
UFM-SDN Appliance Rev 1.5 21. Agregar información de conexión a tierra (GND) Antes de conectar el dispositivo a la línea de alimentación, los tornillos del terminal de la puesta a tierra de protección del dispositivo se deben conectar a la puesta a tierra de protección de la instalación del edificio.
Rev 1.5 26. No utilizar el conmutador como estante ni como espacio de trabajo Cuidado: Equipos montados en deslizadores o rieles no se deben utilizar como estantes ni como espacio de trabajo. La finalidad de los rieles no es deslizar la unidad hacia afuera del bastidor. Sirven solo para la instalación permanente en el lugar de destino final, no para fines de servicio o mantenimiento 27.
UFM-SDN Appliance Rev 1.5 Appendix F: Предупреждения по технике безопасности при установке(Russian) 1. Инструкция по установке Перед подключением оборудования к источнику питания следует ознакомиться с инструкцией по установке. 2. Травмы при переносе тяжелых предметов Для поднятия этого изделия следует задействовать достаточное количество людей. <40 lbs <18 kgs 40 - 70 lbs 18 - 32 kgs 70 - 121 lbs 32 - 55 kgs >121 lbs >55 kgs 3.
Rev 1.5 7. Установка шасси поверх другого оборудования Не устанавливать шасси поверх другого оборудования. Падение шасси может привести к травмам и повреждению оборудования. 8. Опасность поражения электрическим током резервного источника питания В этом изделии установлен резервный источник питания или модуль-заглушка. Если установлен модуль-заглушка, не эксплуатировать изделие со снятой или ненадежно закрепленной крышкой модуля-заглушки. 9.
UFM-SDN Appliance Rev 1.5 15. Утилизация оборудования Это оборудование утилизируется в соответствии с национальными законами и постановлениями. 16. Местные и национальные правила установки электрооборудования Это оборудование устанавливается в соответствии с местными и национальными правилами установки электрооборудования. 17. Правила установки электрооборудования Это устройство устанавливается в соответствии с последним изданием национальных правил установки электрооборудования.
Rev 1.5 21. Добавить информацию о подключении к заземлению Перед подключением этого устройства к сети электропитания следует подсоединить винты заземляющего зажима устройства к защитному заземлению здания. (Информация о подключении к заземлению): В здании должна быть предусмотрена возможность подключения к защитному заземлению, к которому техник должен стационарно подключить оборудование. ТЕХНИК должен убедиться, что розетка, от которой будет питаться оборудование, подключена к защитному заземлению здания.
UFM-SDN Appliance Rev 1.5 27. Директива WEEE В соответствии с Директивой 2002/96/EC (WEEE) отходы электрического и электронного оборудования должны собираться и утилизироваться отдельно от обычных бытовых отходов. Следует утилизировать это изделие и все его части ответственным и экологически безопасным способом. 28. Ограничения для сетей электропитания Норвегии This unit is intended for connection to a TN power system and an IT power system of Norway only.
Rev 1.5 Appendix G: Avertismente privind siguranţa la instalare (Romanian) 1. Instrucţiuni de instalare Citiţi toate instrucţiunile de instalare înainte de a conecta 2. Accidentare cauzată de greutate Apelaţi la un număr suficient de persoane pentru a ridica în siguranţă acest produs. <40 lbs <18 kgs 3.
UFM-SDN Appliance Rev 1.5 7. Suprapunerea cadrului Cadrul nu trebuie să fie suprapus peste niciun alt echipament. În cazul în care cadrul cade, poate cauza leziuni corporale şi deteriorări ale echipamentului. 8. Conexiunea la o sursă de alimentare electrică suplimentară - pericol electric Acest produs include o sursă de alimentare suplimentară sau un spaţiu gol în locul acesteia.
Rev 1.5 15. Eliminarea echipamentului Eliminarea acestui echipament trebuie să se realizeze în conformitate cu toate legile şi regulamentele naţionale. 16. Codurile electrice locale şi naţionale Acest echipament trebuie să fie instalat conform codurilor electrice locale şi naţionale. 17. Codurile ed instalare Acest dispozitiv trebuie să fie instalat în conformitate cu ultima versiune a codurilor electrice naţionale ale ţării în cauză.
UFM-SDN Appliance Rev 1.5 21. Adăugarea de informaţii privind legarea la pământ Înainte de a conecta acest dispozitiv la o linie electrică de energie, şuruburile bornelor de protecţie de legare la pământ ale acestui dispozitiv trebuie să fie conectate la priza de pământ de protecţie din instalaţia clădirii.
Rev 1.5 27. Directiva DEEE În conformitate cu Directiva DEEE 2002/96/CE, toate deşeurile de echipamente electrice şi electronice (EEE) trebuie colectate separat şi nu trebuie eliminate împreună cu deşeurile menajere obişnuite. Eliminaţi acest produs şi toate componentele sale în mod responsabil şi ecologic. 28.
UFM-SDN Appliance Rev 1.5 Appendix H: 安裝安全性警告 (Chinese) 警告使用者:這是甲類的資訊產品,在居住的環境中使用時,可能會造成射頻干擾,在這 種情況下,使用者會被要求採取某些適當的對策。 1. 安裝指示 本設備附有備援電源供應器或在適當位置配有空白蓋板。 2. 因重量導致的人身受傷 為了安全起見,請安排足夠的人員以合力抬起本產品。 <40 lbs <18 kgs 40 - 70 lbs 18 - 32 kgs 70 - 121 lbs 32 - 55 kgs >121 lbs >55 kgs 3. 重設備 本設備極重,應使用機械式起重機來搬移,以避免人員受傷。 4. 安裝於進出管制區域 本設備設計安裝於進出管制區域。 5. 有觸電的危險 有觸電的危險! 拆除風扇模組後,即可接觸到模組空腔內的電源針腳。 請勿將工具或機身零件插入到風扇模組空腔內。 6.
Rev 1.5 7. 堆疊機箱 機箱不應堆疊在任何其他設備上。如果機箱掉落,可能造成人員受傷與設備損 壞。 8. 複式電源連接時的電擊危險 本設備附有備援電源供應器或在適當位置配有空白蓋板。如果是電源供應器空 白蓋板,在空白蓋板已取下或未牢牢固訂的情況下,請勿操作本產品。 9. 雙極 / 中性保險絲 本系統具有雙極 / 中性保險絲。請拔掉所有電源線後,再打開本產品的蓋板或 碰觸任何內部零件。 10. 多電源輸入座 電擊與能源危害的危險。 所有 PSU 均各自獨立。 將所有電源供應器斷電,確保交換器平台內部在電源關閉狀態。 11. 閃電時的電擊危險 在閃電期間,不要使用本設備或連接或拔下纜線。 12. InfiniBand 銅纜連接 / 拔下 InfiniBand 銅纜很重且沒有彈性,因此必須小心裝在連接器上或自連接器上拔 下。如需相關的特殊警告 / 指示,請洽詢纜線製造商。 13. 機架安裝與維修 此產品已安裝在機架中或在機架中維修時,必須採取特定預防措施以確保系統 維持穩定。一般您應該將設備從底部到頂端放滿機架。 14.
UFM-SDN Appliance Rev 1.5 15. 設備棄置 棄置本設備應遵照所有國內法規。 16. 當地與國家電氣法規 請遵照當地與國家電氣法規安裝本設備。 17. 安裝法規 請務必遵循最新版的國家電氣法規,安裝本設備。在北美地區,請務必遵循美 國國家電工法規和加拿大電工法規中的適用規定,安裝本設備。 18. 更換電池 警告:只能以 UL 認可電池,且取得最大異常充電電流低於 4mA 認證的電池進 行更換。 若更換錯誤類型的電池,會有爆炸的危險。 請依據指示棄置廢電池。 19. UL 列名和 CSA 認證電源線 北美地區在接上電源時,請選用獲得 UL 列名和 CSA 認證、三個導體、[16 AWG] 附成型插頭,額定值為 125 V、[13 A],長度至少 1.5 公尺 [ 六英尺 ],但 不超過 4.5 公尺的電源線。 歐洲地區在接上電源時,請選用國際協調式且標示有 字樣、三個導體、 標稱截面至少 1.0 平方公厘,額定值為 300 V,採用 PVC 絕緣的電源線。電源 線需有成型插頭,額定值為 250 V, 10 A。 20. 高漏電流 21.
Rev 1.5 23. 互連設備 連接至 RS232 設備和乙太網路介面的纜線必須是 UL 認證類型 DP-1 或 DP-2。 ( 請注意位於非 LPS 電路時 ) 過電流保護:準備好使用的列名分支電路過電流保護裝置最大額定值 20 A 必須 整合在配線中。 24. 危險的放射線暴露 小心 – 使用非本手冊指定的控制、調整或執行程序可能導致曝露在危險的放射 線下。 配備光纜連接埠的產品 CLASS 1 雷射產品,並參照最新的雷射標準 IEC 60 825-1:1993 + A1:1997 + A2:2001 與 EN 60825-1:1994+A1:1996+ A2:2001 配備光纜連接埠的產品 25. 適當外殼 終端產品廠商或終端使用者應提供適合的電氣、機械和防火外殼。 26. 切換開關不可用作機架或工作空間 小心:滑軌 / 導軌安裝設備不可用作機架或工作空間。導軌不適用於將設備滑 出機架使用。僅限永久安裝在最後安置區域時使用,不可用於維修和保養。 27.
UFM-SDN Appliance Rev 1.