Specification Sheet
Table Of Contents
- INDUSTRY LEADING FEATURES / BENEFITS
- MODEL NUMBER NOMENCLATURE
- STANDARD FEATURES and ACCESSORIES
- DIMENSIONS - OUTDOOR
- CLEARANCES - OUTDOOR
- SPECIFICATIONS - OUTDOOR HEAT PUMP
- PERFORMANCE - HIGH WALL
- PERFORMANCE - CASSETTE
- PERFORMANCE - DUCTED STYLE
- PERFORMANCE - FLOOR CONSOLE
- COMPATIBILITY TABLE
- COOLING PERFORMANCE DATA - HIGH WALL
- HEATING PERFORMANCE DATA - HIGH WALL
- COOLING PERFORMANCE DATA - CASSETTE
- HEATING PERFORMANCE DATA - CASSETTE
- COOLING PERFORMANCE DATA - DUCTED STYLE
- HEATING PERFORMANCE DATA - DUCTED STYLE
- COOLING PERFORMANCE DATA - FLOOR CONSOLE
- HEATING PERFORMANCE DATA - FLOOR CONSOLE
- APPLICATION DATA
- WIRING
- AIR FLOW DATA
- SOUND PRESSURE
- ELECTRICAL DATA
- WIRING DIAGRAMS
- GUIDE SPECIFICATIONS
13
COOLING PERFORMANCE DATA − CASSETTE
MODEL
COOLING OUTDOOR CONDITIONS
Indoor Conditions
DB
77F
(25C)
86F
(30C)
95F
(35C)
104F
(40C)
113F
(45C)
122F
(50C)
DB WB
09
(208-230V)
69.8F
(21C)
59F
(15C)
TC 10.19 10.27 10.06 8.16 7.98 7.16
SC 7.75 7.70 7.64 6.77 6.47 6.09
Input 0.72 0.93 1.23 1.06 0.95 0.90
75.2F
(24C)
62.6F
(17C)
TC 11.32 11.52 11.01 8.99 8.78 7.85
SC 8.49 8.76 8.37 7.19 7.11 6.52
Input 0.72 0.95 1.24 1.07 0.98 0.95
80.6F
(27C)
66.2F
(19C)
TC 12.03 12.59 11.85 9.66 9.43 8.52
SC 8.30 8.56 8.29 7.44 7.64 6.99
Input 0.73 0.96 1.25 1.08 1.03 0.98
89.6F
(32C)
73.4F
(23C)
TC 12.86 13.45 12.35 10.32 10.12 9.25
SC 9.64 10.09 9.39 8.26 8.20 7.49
Input 0.74 1.01 1.28 1.16 1.09 1.01
12
(208-230V)
69.8F
(21C)
59F
(15C)
TC 10.19 10.27 10.06 8.16 7.98 7.16
SC 7.75 7.70 7.64 6.77 6.47 6.09
Input 0.72 0.93 1.23 1.06 0.95 0.90
75.2F
(24C)
62.6F
(17C)
TC 11.32 11.52 11.01 8.99 8.78 7.85
SC 8.49 8.76 8.37 7.19 7.11 6.52
Input 0.72 0.95 1.24 1.07 0.98 0.95
80.6F
(27C)
66.2F
(19C)
TC 12.03 12.59 11.85 9.66 9.43 8.52
SC 8.30 8.56 8.29 7.44 7.64 6.99
Input 0.73 0.96 1.25 1.08 1.03 0.98
89.6F
(32C)
73.4F
(23C)
TC 12.86 13.45 12.35 10.32 10.12 9.25
SC 9.64 10.09 9.39 8.26 8.20 7.49
Input 0.74 1.01 1.28 1.16 1.09 1.01
18
(208-230V)
69.8F
(21C)
59F
(15C)
TC 11.21 12.77 17.16 12.51 11.87 10.88
SC 9.48 10.04 12.22 10.02 9.49 8.81
Input 0.66 1.07 1.90 1.50 1.39 1.26
75.2F
(24C)
62.6F
(17C)
TC 12.46 14.33 18.30 13.60 12.91 12.13
SC 9.72 10.45 12.62 10.22 9.68 9.10
Input 0.69 1.26 1.92 1.35 1.32 1.23
80.6F
(27C)
66.2F
(19C)
TC 13.67 16.73 19.15 15.51 14.46 13.67
SC 9.88 11.34 12.64 11.17 10.85 9.84
Input 1.00 1.51 1.94 1.56 1.44 1.31
89.6F
(32C)
73.4F
(23C)
TC 14.25 17.41 19.74 16.98 15.57 14.47
SC 10.27 11.74 13.27 11.61 11.28 10.74
Input 1.02 1.59 1.96 1.61 1.50 1.38
LEGEND
DB - Dry Bulb
WB - Wet Bulb
TC - Total Net Capacity (1000 Btu/hour)
SC - Sensible Capacity (1000 Btu/hour)
Input - Total Power (kW)
HEATING PERFORMANCE DATA − CASSETTE
MODEL
HEATING OUTDOOR CONDITIONS (DB)
Indoor Conditions
DB
-13F
(-25C)
-4F
(-20C)
0F
(-17C)
5F
(-15C)
17F
(-8C)
19.4F
(-7C)
24.8F
(-4C)
32F
(0C)
39.2F
(4C)
44.6F
(7C)
53.6F
(12C)
09
(208-230V)
59F
(15C)
TC 8.23 9.58 10.31 11.01 13.28 13.57 13.99 14.39 14.90 15.56 16.99
Input 1.68 1.76 1.76 1.76 1.80 1.76 1.63 1.44 1.41 1.38 1.36
COP 1.44 1.60 1.72 1.83 2.17 2.26 2.51 2.92 3.11 3.30 3.66
64.4F
(18C)
TC 7.75 9.12 10.01 10.72 12.81 13.04 13.39 13.58 14.19 15.15 16.39
Input 1.70 1.78 1.82 1.82 1.89 1.81 1.67 1.48 1.46 1.43 1.42
COP 1.34 1.51 1.61 1.72 1.99 2.11 2.35 2.69 2.85 3.10 3.38
69F
(20.5C)
TC 7.32 8.74 9.76 10.47 12.46 12.57 12.76 12.85 13.76 14.62 15.88
Input 1.72 1.80 1.90 1.90 1.98 1.89 1.72 1.50 1.51 1.50 1.49
COP 1.25 1.43 1.51 1.62 1.85 1.95 2.17 2.51 2.67 2.85 3.12
71.6F
(22C)
TC 7.02 8.35 9.47 10.22 12.01 12.06 12.26 12.36 13.27 14.13 15.39
Input 1.74 1.83 1.93 1.92 2.01 1.91 1.77 1.54 1.58 1.55 1.53
COP 1.18 1.34 1.44 1.56 1.75 1.85 2.03 2.35 2.46 2.67 2.95
12
(208-230V)
59F
(15C)
TC 8.48 9.86 10.62 11.34 13.68 13.97 14.41 14.82 15.34 16.03 17.49
Input 1.72 1.80 1.80 1.81 1.84 1.80 1.67 1.48 1.44 1.42 1.39
COP 1.44 1.61 1.73 1.84 2.18 2.28 2.53 2.94 3.12 3.32 3.68
64.4F
(18C)
TC 7.98 9.40 10.31 11.04 13.20 13.43 13.79 13.99 14.62 15.61 16.88
Input 1.74 1.82 1.87 1.87 1.93 1.86 1.71 1.52 1.50 1.47 1.46
COP 1.34 1.51 1.62 1.73 2.00 2.12 2.36 2.70 2.86 3.11 3.40
69F
(20.5C)
TC 7.54 9.01 10.05 12.22 12.83 12.94 13.14 13.23 14.17 15.06 16.36
Input 1.77 1.85 1.95 1.98 2.03 1.94 1.77 1.55 1.56 1.55 1.53
COP 1.25 1.43 1.51 1.81 1.85 1.95 2.17 2.51 2.67 2.85 3.12
71.6F
(22C)
TC 7.23 8.60 9.75 10.52 12.37 12.42 12.63 12.73 13.66 14.55 15.85
Input 1.78 1.87 1.98 1.97 2.06 1.96 1.81 1.58 1.62 1.59 1.57
COP 1.19 1.34 1.44 1.56 1.76 1.86 2.04 2.36 2.47 2.68 2.96
18
(208-230V)
59F
(15C)
TC 13.81 17.11 18.18 21.00 21.86 22.11 23.06 24.69 25.80 26.81 28.10
Input 2.45 2.73 2.62 2.97 2.76 2.69 2.62 2.66 2.47 2.35 2.22
COP 1.65 1.84 2.03 2.07 2.32 2.41 2.58 2.72 3.06 3.35 3.71
64.4F
(18C)
TC 13.12 16.32 17.45 20.23 21.07 21.36 22.12 23.45 24.53 25.78 26.80
Input 2.53 2.78 2.83 3.09 2.87 2.75 2.68 2.74 2.56 2.42 2.26
COP 1.52 1.72 1.81 1.92 2.15 2.28 2.42 2.51 2.81 3.12 3.48
69F
(20.5C)
TC 12.59 15.67 16.68 19.01 20.59 20.89 21.34 22.54 23.79 24.63 25.40
Input 2.55 2.82 2.89 3.18 2.93 2.82 2.77 2.81 2.67 2.53 2.43
COP 1.45 1.63 1.69 1.75 2.06 2.17 2.26 2.35 2.61 2.85 3.06
71.6F
(22C)
TC 12.09 14.72 15.97 18.15 20.16 20.34 20.91 21.53 22.57 23.53 24.00
Input 2.67 2.82 2.98 3.32 3.25 3.19 2.95 2.75 2.60 2.59 2.40
COP 1.35 1.53 1.57 1.60 1.82 1.87 2.08 2.29 2.54 2.67 2.93
LEGEND
DB - Dry Bulb
TC - Total Net Capacity (1000 Btu/hour)
Input - Total Power (kW)