Test Descriptions
TEST_01 - CPA Registration
TEST_01 - CPA Registration
Description
This test reads and decodes the phone’s Reverse Control Channel
(RECC) and outputs the following registration information:
Phone number: <decimal number>
MIN: <hexadecimal number>
Serial number: <decimal number>, <decimal number>, <
hexadecimal number>
Power Class: <class I, II, or III>
Transmission: <continuous or discontinuous>
Bandwidth: <20 MHz or 25 MHz>
NOTE
Regarding the serial number data shown above, the numbers are as
follows:
First Decimal Number: The first three digits represent the
manufacturer’s code. The next eight digits represent a combination of
the reserve bits and the unit serial number.
Second Decimal Number: The first three digits represent the
manufacturer’s code. The next two digits represent the reserve bits. The
next six digits represent the unit serial number.
Hexadecimal Number: A hexadecimal representation of the above two
numbers.
The test works as follows:
The test system transmits the Registration ID message repeatedly,
with the value of the REGID field set alternately to 0 and 500. This
induces the phone to register with the test system.
If an error occurs in this test, all testing is stopped.
A CPA/CPD Registration or CPA/CPD Origination test must be run at
least once before any analog tests can be run, otherwise the operator is
prompted to enter the MSUT phone number during testing. After a
CPA/CPD Registration or CPA/CPD Origination test is run once it does
not need to be run again for the test system to be able to perform other
analog tests. The registration data is remembered unless it is erased by
loading new test software, registering a different radio, or executing a
SCRATCH C command in IBASIC.
Pass/Fail Limits Used
None