User`s guide

84 Chapter 2
S:\agilent\83217\OPT001\BOOK\CHAPTERS\tdscrip.fm
Test Descriptions
TEST_38 - RXD Traffic Channel FER
TEST_38 - RXD Traffic Channel FER
Description
This test measures the performance of the mobile station when
demodulating a forward traffic channel in an additive white gaussian
noise (AWGN) environment (no fading or multipath). The performance
of the mobile station is determined by the frame error rate (FER).
1. A Service Option 2 (or 9 if parameter 19. RT Rate Set Selection
[0=9600 1=14400] is set to 1) call is attempted, unless a Service
Option 2 or 9 call is already connected. If the MSUT has not
registered, the call attempt may be unsuccessful and the error
message “Failed to establish a call in test <>” will be displayed. To
correct this problem, perform the CPD Registration test.
2. Sector A Power is set to -55 dBm.
3. AWGN is set to -54 dBm.
4. The RXD Maximum Frames for FER parameter is retrieved and that
value is entered in the Max Frames field.
5. The FER test is turned on with a confidence limit of 95%.
6. Traffic Channel level and data rates are set up and the first test is
triggered. The software waits for an GPIB interrupt to determine
when the test is done. The test times out and continues if the
interrupt does not occur within a period bounded by the RXD
Maximum Frames for FER parameter. If a timeout occurs, a timeout
message is displayed. This process is repeated for each of the six
tests specified in EIA/TIA
IS-98A.
7. The following measurement results are printed to the TESTS
(IBASIC Controller) screen. (For each test, FER %, number of frames
counted and number of errors counted is displayed):
Traf Chan FER w/AWGN Ec/Ior=-16.3 & Eb/Nt=3.8
1
Traf Chan FER w/AWGN Ec/Ior=-15.8 & Eb/Nt=4.3
Traf Chan FER w/AWGN Ec/Ior=-15.6 & Eb/Nt=4.5
Traf Chan FER w/AWGN @ 4800bps & Eb/Nt=4.0
Traf Chan FER w/AWGN @ 2400bps & Eb/Nt=4.5
Traf Chan FER w/AWGN @ 1200bps & Eb/Nt=4.6
1. These measurement results are for cellular and rate set 1 only.