Operation Manual

42ADF025, 42ADF035
Display of Selected Functions
GB
ENGLISH
9
Table II: Unit protection device
Type of protection Effect of protection Operation mode When on
Indoor coil high temperature
protection
Compressor speed slow down
or off
Heating and Auto mode During unit operation at high
ambient
Indoor coil freeze up
protection
Compressor speed slow down
or off
Cooling, Dry and Auto mode During unit operation at low
ambient
Discharge gas high
temperature protection
Compressor speed slow down
or off
Cooling, Heating, Dry and
Auto mode
During unit operation at high
ambient
Defrost cycle Indoor fan off Heating and Auto mode During unit operation at low
and humid ambient
Against frequent compressor
cycling
Against frequent compressor
cycling
Cooling, Heating, Dry and
Auto mode
During unit operation
WARNING:
During heat pump operation the unit will undergo several defrost cycles to remove ice that might collect on the outdoor unit in very
low ambient temperatures. In these cycles, fan speed will automatically stop, can not be varied until defrost cycle is completed.
1. Heating (heat pump models only)
Ventilation (fan only)
• Heating (heat pump models only)
• Automatic (heat pump models only)
• Cooling and dehumidification
• Dehumidification only
2. Signal transmission symbol
3. Temperature selected
4. Address selected
5. Temperature unit of measurement (°C or °F)
6. Unit configuration
7. Batteries exausted indicator
8. Louvre positioning (Flap)
9. Fan speed
10. Powerful mode
11. Economical mode
12. ON timer selected
13. Night timer active
14. DAILY timer active (Everyday)
15. ON timer and OFF timer or current time
16. OFF timer selected