APPENDIX A — LOCAL DISPLAY TABLES
MODE — RUN STATUS
ITEM EXPANSION RANGE UNITS CCN POINT WRITE STATUS PAGE NO.
VIEW
AUTO VIEW OF RUN STATUS
HVAC
ascii string spelling out the hvac modes string 75
OCC
Occupied ? YES/NO OCCUPIED forcible 75
MAT
Mixed Air Temperature dF MAT 75
EDT
Evaporator Discharge Tmp dF EDT 75
LAT
Leaving Air Temperature dF LAT 75
EC.C.P
Economizer Control Point dF ECONCPNT 75
ECN.P
Economizer Act.Curr.Pos. 0-100 % ECONOPOS 75
CL.C.P
Cooling Control Point dF COOLCPNT 75
C.CAP
Current Running Capacity CAPTOTAL 75
HT.C.P
Heating Control Point dF HEATCPNT 75
HT.ST
Requested Heat Stage HT_STAGE 75
H.MAX
Maximum Heat Stages HTMAXSTG 75
ECON
ECONOMIZER RUN STATUS
ECN.P
Economizer Act.Curr.Pos. 0-100 % ECONOPOS 75
ECN.C
Economizer Act.Cmd.Pos. 0-100 % ECONOCMD forcible 75
ACTV
Economizer Active ? YES/NO ECACTIVE 75
DISA
ECON DISABLING CONDITIONS 75
DISA
UNAV
Econ Act. Unavailable? YES/NO ECONUNAV 75
DISA
R.EC.D
Remote Econ. Disabled ? YES/NO ECONDISA 75
DISA
DBC
DBC - OAT Lockout? YES/NO DBC_STAT 75
DISA
DEW
DEW - OA Dewpt.Lockout? YES/NO DEW_STAT 75
DISA
DDBC
DDBD- OAT > RAT Lockout? YES/NO DDBCSTAT 75
DISA
OAEC
OAEC- OA Enth Lockout? YES/NO OAECSTAT 75
DISA
DEC
DEC - Diff.Enth.Lockout? YES/NO DEC_STAT 75
DISA
EDT
EDT Sensor Bad? YES/NO EDT_STAT 75
DISA
OAT
OAT Sensor Bad ? YES/NO OAT_STAT 75
DISA
FORC
Economizer Forced ? YES/NO ECONFORC 75
DISA
SFON
Supply Fan Not On 30s ? YES/NO SFONSTAT 75
DISA
CLOF
Cool Mode Not In Effect? YES/NO COOL_OFF 75
DISA
OAQL
OAQ Lockout in Effect ? YES/NO OAQLOCKD 75
DISA
HELD
Econ Recovery Hold Off? YES/NO ECONHELD 75
O.AIR
OUTSIDE AIR INFORMATION 75
O.AIR
OAT
Outside Air Temperature dF OAT forcible 75
O.AIR
OA.RH
Outside Air Rel. Humidity % OARH forcible 75
O.AIR
OA.E
Outside Air Enthalpy OAE 75
O.AIR
OA.D.T
OutsideAir Dewpoint Temp dF OADEWTMP 75
COOL
COOLING INFORMATION
C.CAP
Current Running Capacity % CAPTOTAL 75
CUR.S
Current Cool Stage COOL_STG 75
MAX.S
Maximum Cool Stages CLMAXSTG 75
DEM.L
Active Demand Limit DEM_LIM forcible 75
SUMZ
COOL CAP. STAGE CONTROL 75
SUMZ
SMZ
Capacity Load Factor % SMZ 75
SUMZ
ADD.R
Next Stage EDT Decrease deltaF ADDRISE 75
SUMZ
SUB.R
Next Stage EDT Increase deltaF SUBRISE 75
SUMZ
R.PCT
Rise Per Percent Capacity RISE_PCT 75
SUMZ
Y.MIN
Cap Deadband Subtracting Y_MINUS 75
SUMZ
Y.PLU
Cap Deadband Adding Y_PLUS 75
SUMZ
Z.MIN
Cap Threshold Subtracting Z_MINUS 75
SUMZ
Z.PLU
Cap Threshold Adding Z_PLUS 76
SUMZ
H.TMP
High Temp Cap Override HI_TEMP 76
SUMZ
L.TMP
Low Temp Cap Override LOW_TEMP 76
SUMZ
PULL
Pull Down Cap Override PULLDOWN 76
SUMZ
SLOW
Slow Change Cap Override SLO_CHNG 76
TRIP
MODE TRIP HELPER
UN.C.S
Unoccup. Cool Mode Start UCCLSTRT 76
UN.C.E
Unoccup. Cool Mode End UCCL_END 76
OC.C.S
Occupied Cool Mode Start OCCLSTRT 76
OC.C.E
Occupied Cool Mode End OCCL_END 76
TEMP
Ctl.Temp RAT,SPT or Zone CTRLTEMP 76
OC.H.E
Occupied Heat Mode End OCHT_END 76
OC.H.S
Occupied Heat Mode Start OCHTSTRT 76
UN.H.E
Unoccup. Heat Mode End UCHT_END 76
UN.H.S
Unoccup. Heat Mode Start UCHTSTRT 76
HVAC
ascii string spelling out the hvac modes string 76
LINK
CCN - LINKAGE
MODE
Linkage Active - CCN ON/OFF MODELINK 76
L.Z.T
Linkage Zone Control Tmp dF LZT76
L.C.SP
Linkage Curr. Cool Setpt dF LCSP 76
L.H.SP
Linkage Curr. Heat Setpt dF LHSP 76
HRS
COMPRESSOR RUN HOURS
HR.A1
Compressor A1 Run Hours 0-999999 HRS HR_A1 config 76
HR.A2
Compressor A2 Run Hours 0-999999 HRS HR_A2 config 76
HR.B1
Compressor B1 Run Hours 0-999999 HRS HR_B1 config 76
HR.B2
Compressor B2 Run Hours 0-999999 HRS HR_B2 config 76
STRT
COMPRESSOR STARTS
ST.A1
Compressor A1 Starts 0-999999 CY_A1 config 76
ST.A2
Compressor A2 Starts 0-999999 CY_A2 config 76
ST.B1
Compressor B1 Starts 0-999999 CY_B1 config 76
ST.B2
Compressor B2 Starts 0-999999 CY_B2 config 76