UNIT CHARACTERISTICS
Model
N280416GXXX N280426GXXX N280425GXXX N280446GXXX
Dimensional Data
Height 28” / 711.2 mm
Width 11.5” / 292.1 mm
Depth 14” / 355.6 mm
Unit Weight 84 lbs / 38 kg 84 lbs / 38 kg 92 lbs / 42 kg 98 lbs / 44 kg
Unit Protection Rating Type 12/4/4X/3R
Cooling Data
Refrigerant R134a
Refrigerant Charge 11 oz.
Cooling Capacity at 95 F Enclosure
95 F Ambient (BTU/Hr.)
3589/3974 3690 3298 3690
Cooling Capacity at Max Conditions
(BTU/Hr.)
3805/4162 4394 3818 4394
Maximum Ambient Temp 125 F / 52 C
Minimum Ambient Temp -40 F / -40 C
Enclosure Airflow 143 CFM
External Airflow 288 CFM
Condensate Management Hose discharge / Optional powered C/E
Heating Data
Capacity 1300 W N/A
Electrical Data
Rated Voltage (50/60 Hz) 115 V 230 V 230 V 460 V
Rated Frequency 50 / 60 Hz 60 Hz 50 Hz 60 Hz
Voltage Range +/- 10% of rated
Cooling Amps at Max Conditions 11.6/11.2 6.5 5.8 3.3
Heating Amps 12.2 6.2 6.2 N/A
Compressor RLA / LRA 8.1/40.0 24.5 5.3 24.5
Evaporator Fan RLA .38/.36 .19 .18 .19
Condenser Fan RLA .78/.93 .53 .39 .53