Refrigerator User Manual

SECTION 3
3-25 T-268-07
S Real Time Clock (RTC) Modification
S Pre-Trip result & data
S Trip Start
S ISO Trip Header (Must be entered first via
Interrogation program)
S Economy Mode Start
S Economy Mode End
S “Auto 2” Pre-Trip Start
S “Auto 2” Pre-Trip End
S Bulb Mode Start
S B ulb Mode changes
S B ulb Mode End
S USDA Trip Comment
S CTD Controlled Atmosphere Information
S Humidification Start
S Humidification End
S USDA Probe Calibration
3.3.2 DataCORDER Configuration
NOTE
The DataCORDER software is integrated with
the C ontroller software.
Configuration to factory installed default configuration
is achieved via a common configuration card used for
controller functions, see section 3.1.2.
Changes t o the factory default configuration must be
made with the Interrogation device.
Configuration:
Tells the operational software what physical
components are built into the container unit, how many
sensors to record, what recording i nterval should be
used, etc..
ITEM SETTING
F ACTORY
DEFAULT
Sensor Logging
(Network)
Average or
Snapshot
Average
Sensor Logging
(Thermistor)
Average,
Snapshot or
USDA
Average
Sensor Format 1or2byte 1 byte
Sensor
Configuration
Refer to section
3.3.5.f.
2 sensors
Logging Interval
15, 30, 60 or
120 minutes
60 minutes
Configuration cards are available thru CTD
Replacement Components Group.
The use of a programming card in the field should only
occur under unusual circumstances, such as a physical
component in the container unit i s changed to a different
component, resulting in a new configuration for the
unit.