GENERAL
NFORMATON
Section 1 -- General Information
Carrier Air-cooled 7 kW, 12 kW and 15 kW Generators
1.5 SPECIFICATIONS
1.5.1 GENERATOR
Model
Rated Max. Continuous Power Capacity (Watts*)
Rated Voltage
Rated Max. Continuous Load Current (Amps)
120 Volts**
240 Volts
Main Line Circuit Breaker
Phase
Number of Rotor Poles
Rated AC Frequency
Power Factor
Recommended Air Filter
Battery Requirement
(At 0° F -17.8 ° C)
Weight
Output Sound Level @23 ft (7m) at full load
Normal Operating Range
ASPAS1 CCA007
6,000 NG/7,000 LP
120/240
ASPAS1CCA012
12,000 NG/12,000 LP
120/240
ASPASICCA015
13,000 NG/15,000 LP
120/240
50.0 NG/58.3 LP 100.0
25.0 NG/29.2 LP 50.0
30 Amp
1
2
60 Hz
1
Carrier Part # 0C8127
Group 26
12 Volts and
350 Cold-cranking
Amperes Minimum
375 Pounds
68 db (A)
NG/100.0 LP 108.3
NG/50.0 LP 54.2
50 Amp
1
2
60 Hz
1
Carrier Part # 0C8127
Group 26
12 Volts and
525 Cold-cranking
Amperes Minimum
470 Pounds
70.5 db (A)
-20°F (-28.8°C) to 104°F (40°C)
NG/125.0 LP
NG/62.5 LP
65 Amp
1
2
60 Hz
1
Carrier Part # 0C8127
Group 26
12 Volts and
525 Cold-cranking
Amperes Minimum
487 Pounds
71.5 db (A)
* Maximum wattage and current are subject to and timlted by such factors as fuel atu content, ambient temperature, altitude, engine power and condition, etc. Maximum power decreases about 3.5
percent for each 1000 feet above sea level: and also will decrease about 1 percent for each 6" O (10° F) above 16° C (60° F) ambient temperature.
** Load current values shown for 120 volts are maximum TOTAL values for two separate circuits.The maximum current in each circuit must not exceed the value stated for 240 volts.
1.5.2 ENGINE
Type of Engine
Number of Cylinders
Rated Horsepower
Displacement
Cylinder Block
Valve Arrangement
Ignition System
Recommended Spark Plug
Spark Plug Gap
Compression Ratio
Starter
Oil Capacity Including Filter
Recommended Oil Filter
Recommended Air Filter
Operating RPM
ASPASICCA007
GH-410
1
14.5 @ 3,600 rpm
410cc
Aluminum w/Cast
iron Sleeve
Overhead Valves
Solid-state w/Magneto
RC 14YC
0.76 mm (0.030 inch)
8.6:1
12 Vdc
Approx. 1.5 Qts
Carrier Part # 70185D
Carrier Part # 0C8127
3,600
ASPAS1CCA012
GT-990
2
30 @ 3,600 rpm
992cc
Aluminum w/Cast
iron Sleeve
Overhead Valves
Solid-state w/Magneto
RC12YC
0.508 mm (0.020 inch)
9.5:1
12 Vdc
Approx. 1.7 Qts
Carrier Part # 70185D
Carrier Part # 0C8127
3,600
ASPASlCCA015
GT-990
2
30 @ 3,600 rpm
992cc
Aluminum w/Cast
iron Sleeve
Overhead Valves
Solid-state w/Magneto
RC12YC
0.508 mm (0.020 inch)
9.5:1
12Vdc
Approx. 1.7 Qts
Carrier Part # 70185D
Carrier Part # 0C8127
3,600
1.6 SYSTEM SET LED
The "System Set" LED is lit when all of the following
conditions are true:
1. The AUTO/OFF/MANUAL switch is set to the AUTO
position.
2. The utility voltage being supplied to the unit is being
sensed by the PCB. If the utility sense voltage is not
connected to the unit or if it is below 168 volts AC,
then the system set light will flash rapidly. This
indicates that if the AUTO/OFF/ MANUAL switch is
placed in the Auto position, the generator will start.
3. The "Not In Auto" dip switch is set to the OFF position
on the control board.
6 Carrier
4. No alarms are present, for example, low oil pressure,
high temperature, etc.
1.7 FUEL REQUIREMENTS
AND RECOMMENDATIONS
With LP gas, use only the vapor withdrawal
system, This type of system uses the vapors formed
above the liquid fuel in the storage tank. The engine has
been fitted with a fuel carburetion system that meets the
specifications of the 1997 California Air Resources Board
for tamper-proof dual fuel systems. The unit will run on
natural gas or LP gas, but it has been factory set to run
on natural gas.