Table 10 — Electrical Data, 48ZG,ZN050 Units
LEGEND NOTE: Units use 1 (low heat) or 2 (high heat) combustion fan motors rated at
0.3 FLA each.
NOMINAL
VOLTAGE
(3 Ph 60 Hz)
VOLTAGE
RANGE
COMPRESSOR
OFM IFM
EXHAUST
FAN
POWER SUPPLY
No. 1 No. 2
RLA LRA RLA LRA Qty
Total
FLA
Hp FLA
Total
Hp
Total
FLA
MCA MOCP
208/230 187-254 89.7 446 69.2 345 3
6.6
(ea)
7
1
/
2
24.2/22.0
—/— 225.3/223.1 300/300
6 21.2/19.2 246.5/242.3 300/300
10 33.4/30.4 258.7/253.5 300/300
15 48.4/44.0 273.7/267.1 350/350
20 61.6/56.0 286.9/279.1 350/350
10 30.8/28.0
—/— 231.9/229.1 300/300
6 21.2/19.2 253.1/248.3 300/300
10 33.4/30.4 265.3/259.5 350/300
15 48.4/44.0 280.3/273.1 350/350
20 62.0/56.0 293.5/285.1 350/350
15 46.2/42.0
—/— 247.3/243.1 300/300
6 21.2/19.2 268.5/262.3 350/350
10 33.4/30.4 280.7/273.5 350/350
15 48.4/44.0 295.7/287.1 350/350
20 62.0/56.0 308.9/299.1 350/350
20 59.4/54.0
—/— 260.5/255.1 350/300
6 21.2/19.2 281.7/274.3 350/350
10 33.4/30.4 293.9/285.5 350/350
15 48.4/44.0 308.9/299.1 350/350
20 62.0/56.0 322.1/311.1 400/400
25 74.8/68.0
—/— 275.9/269.1 350/350
6 21.2/19.2 297.1/288.3 350/350
10 33.4/30.4 309.3/299.5 350/350
15 48.4/44.0 324.3/313.1 400/400
20 62.0/56.0 337.5/325.1 400/400
460
414-508 43.6 223 34.6 173 3
3.3
(ea)
7
1
/
2
11.0
110.0 150
6 9.6 119.6 150
10 15.2 125.2 150
15 22.0 132.0 175
20 28.0 138.0 175
10 14.0
113.0 150
6 9.6 122.6 150
10 15.2 128.2 150
15 22.0 135.0 175
20 28.0 141.0 175
15 21.0
120.0 150
6 9.6 129.6 150
10 15.2 135.2 175
15 22.0 142.0 175
20 28.0 148.0 175
20 27.0
126.0 150
6 9.6 135.6 175
10 15.2 141.2 175
15 22.0 148.0 175
20 28.0 154.0 175
25 34.0
133.0 175
6 9.6 142.6 175
10 15.2 148.2 175
15 22.0 155.0 175
20 28.0 161.0 200
30 40.0
139.0 175
6 9.6 148.6 175
10 15.2 154.2 175
15 22.0 161.0 200
20 28.0 167.0 200
575
518-632 36.5 164 26.7 120 3
2.4
(ea)
7
1
/
2
9.0
88.5 125
6 7.8 96.3 125
10 12.2 100.7 125
15 18.0 106.5 125
20 22.0 110.5 125
10 11.0
90.5 125
6 7.8 98.3 125
10 12.2 102.7 125
15 18.0 108.5 125
20 22.0 112.5 125
15 17.0
96.5 125
6 7.8 104.3 125
10 12.2 108.7 125
15 18.0 114.5 150
20 22.0 118.5 150
20 22.0
101.5 125
6 7.8 109.3 125
10 12.2 113.7 150
15 18.0 119.5 150
20 22.0 123.5 150
25 27.0
106.5 125
6 7.8 114.3 150
10 12.2 118.7 150
15 18.0 124.5 150
20 22.0 128.5 150
FLA Full Load Amps
Hp Nominal Horsepower
IFM Indoor (Supply) Fan Motor
LRA Locked Rotor Amps
MCA Minimum Circuit Amps (for wire sizing)
MOCP Maximum Overcurrent Protection
OFM Outdoor (Condenser) Fan Motor
RLA Rated Load Amps