Carson Manufacturing Co., Inc. 5451 North Rural Street Indianapolis, IN 46220 Phone: (888) 577-6877 Fax: (317) 254-2667 www.carsonsirens.
Page 2 of 16 SC-1002 / 1012 / 1022-10 14 Installation Instructions TABLE OF CONTENTS GENERAL DESCRIPTION .................................................................................... 3 SPECIFICATIONS................................................................................................. 3 INSTALLATION ..................................................................................................... 4 SAFETY PRECAUTIONS ....................................................................
SC-1002 / 1012 / 1022-10 14 Installation Instructions Page 3 of 16 GENERAL DESCRIPTION The SC-1000 Series Siren Amplifier with Light Control is designed for single 100W speaker use. The SC-1002 and SC-1012 are a console unit and remote unit respectively. The SC-1022 is a remote hand held unit with pushbutton controls. SC-1002 / 1012 - The primary operating modes are Mechanical, Wail, Yelp, and Standby selected by 3-position rocker switches.
Page 4 of 16 SC-1002 / 1012 / 1022-10 14 Installation Instructions INSTALLATION Proper installation of the unit is essential for years of safe, reliable operation. Please read all instruction before installing the unit. Failure to follow these instructions can cause serious damage to the unit or vehicle and may void warranties. SAFETY PRECAUTIONS For the safety of the installer, vehicle operator, passengers and the community please observe the following safety precautions.
SC-1002 / 1012 / 1022-10 14 Installation Instructions Page 5 of 16 OPTION SWITCHES An internal 8-position DIP switch on the circuit board may be changed to select various options. Accessing Option Switches - the DIP switch is located just behind the front panel of the amplifier. Use a 7/64” allen wrench to remove the 4 corner screws then remove front panel.
Page 6 of 16 SC-1002 / 1012 / 1022-10 14 Installation Instructions MOUNTING (Main unit) The mounting bracket supplied can be installed above or below the unit. Mounting bolts slide into channels on each side of the case. Lockwashers should be used between the case and bracket as well as between the bracket and nut. Choose a mounting location convenient to the operator and away from any air bag deployment areas. Inspect behind mounting area for clearance. Assure adequate ventilation to prevent overheating.
SC-1002 / 1012 / 1022-10 14 Installation Instructions Page 7 of 16 ELECTRICAL CONNECTIONS Electrical connections to the unit are made using terminal block plugs and screw terminals located on the amplifier. Labels on the unit identify each terminal function. Install the plug on the unit before wiring. If the unit needs service the plug can be easily removed without unwiring.
Page 8 of 16 SC-1002 / 1012 / 1022-10 14 Installation Instructions ELECTRICAL CONNECTIONS CONTINUED (ALL MODELS) +VDC HORN RING SWITCH +VDC HORN RING SWITCH SPLICE Added SPDT Switch MOMENTARY FOOT SWITCH HORN For Aux Input Connection If just a splice is made to vehicle horn circuit, the vehicles horn will also sound with the siren.
SC-1002 / 1012 / 1022-10 14 Installation Instructions Page 9 of 16 ELECTRICAL CONNECTIONS CONTINUED (SC-1012 only) Front of Unit REMOTE PANEL LT2 LT1 HORN PHSR MECH YELP MAN AUTO LAMP NEG Plug into unit first for terminal identification 10-P Terminal Block Plug (CP4688-10) Plug installed this orientation Remote Panel wired to terminal block plug Suggest wires be #22 AWG (not supplied) NEG AUTO MAN YELP MECH HORN PHSR LT1 LT2 LAMP Note Top Orientation SC-1012 MAN MECH PHSR YELP
Page 10 of 16 SC-1002 / 1012 / 1022-10 14 Installation Instructions ELECTRICAL CONNECTIONS CONTINUED (SC-1022 only) Front of Unit HAND CONTROL Plug hand control into unit SC-1022 MAN HORN MECH WAIL YELP PHSR LT1 LT2 Note: Cable may be extended with ED1753 Hand Control Cable Extension Kit. See PARTS and ACCESSORIES Section. Do not extend with other cables which may cause unreliable operation or damage.
SC-1002 / 1012 / 1022-10 14 Installation Instructions Page 11 of 16 OPERATION SC-1002 and SC-1012 Models Sound Hazard - Sound level from siren speaker (>120dBA @ 10 feet) may cause hearing damage. Do not operate siren without adequate hearing protection for you and anyone in immediate vicinity. (Ref. OSHA 1910.95 for occupational noise exposure guidelines) POWER ON/OFF The unit is enabled (turned on) by applying positive voltage to the orange enable lead. On the SC-1002, backlight turns on.
Page 12 of 16 SC-1002 / 1012 / 1022-10 14 Installation Instructions OPERATION (SC-1002 and SC-1012 Models continued) LIGHT CONTROLS LT1 and LT2 LIGHTED ROCKER SWITCHES When turned on the rocker switch will light up and activate the corresponding light output.
SC-1002 / 1012 / 1022-10 14 Installation Instructions Page 13 of 16 OPERATION (continued) SC-1022 Model Sound Hazard - Sound level from siren speaker (>120dBA @ 10 feet) may cause hearing damage. Do not operate siren without adequate hearing protection for you and anyone in immediate vicinity. (Ref. OSHA 1910.95 for occupational noise exposure guidelines) POWER ON/OFF The unit is enabled (turned on) by applying positive voltage to the orange enable lead.
Page 14 of 16 SC-1002 / 1012 / 1022-10 14 Installation Instructions SERVICE This unit is designed to provide years of reliable service under even the worst conditions. Many times there may appear to be a problem with the unit when the true problem is in the speaker, controlled devices, or improper installation. The following chart shows typical symptoms and possible causes. A blown siren fuse doesn't necessarily mean that the unit is bad.
SC-1002 / 1012 / 1022-10 14 Installation Instructions Page 15 of 16 PARTS and ACCESSORIES The following parts and accessories are available from Carson Manufacturing Company, Inc.
Page 16 of 16 SC-1002 / 1012 / 1022-10 14 Installation Instructions RETURNS If you have any questions concerning this or any other Carson product, please contact our Service Department at (888) 577-6877. Many issues can be handled over the phone. We can also be reached via e-mail at service@carsonsirens.com If a product must be returned for any reason, please contact our Technical Service Department to obtain a Returned Merchandise Authorization number (RMA#) before you ship the product to Carson.