Outdoor Ceiling Fan User Manual

13
SEND SIGNAL
LED

Fan Control
To start the fan. Press the selected speed button to run the fan at the desired speed.
LO=Low speed MED=Medium speed HI=High speed
To turn off the fan. Press the FAN OFF button.
Airflow Direction
To reverse the airflow press the REVERSE button. Reverse operates at any speed whether fan
is on or off. The fan returns to its set speed after reversing.
Light Control
Turn the light on or off independently from the fan by pressing the LIGHT button. Keep
pressing the button in excess of 0.7 seconds, it becomes a dimmer. The light varies from
‘bright’ to ‘dim’ over approximately 8 seconds. This sequence will reverse the light when it
reaches the brightest or dimmest level if you continue to hold the LIGHT button. Release
the button when the desired level is reached.
Memory Feature
The last light function and fan speed will resume when power is turned back on.
Auto Resume
Quick (pressing less than 0.7 seconds) on/off operation of the LIGHT button maintains the
desired brightness level set previously.
 IF FAN DOES NOT WORK
If the fan is not functioning after installation:
Step 1. Check to make sure that batteries are installed correctly
in the control.
Step 2. Turn the power off to the fan (from the circuit breaker)
for at least 5 seconds.
Step 3. Turn the power back on (at the circuit breaker) and push
the Hi, Med, and Low buttons–in that order–within 20 seconds.
Step 4. The fan should now function properly.
 CHANGING FREQUENCY SETTING
You will only have to change the dip switch settings in the remote if
you are using more than one fan in the same area and want to control
them separately.
Step 1. At the circuit breaker or fuse box, turn the power off for the
fan you want to change.
Step 2.OpenthebatterydooroftheVersa•Touchcontrolandremove
the batteries.
Step 3. Change the dip switch settings, assuring that they are different
fromthepreviouslyinstalledVersa•Touchfan.
Step 4. Re-install the batteries and the battery door on the control.
Step 5. At the circuit breaker or fuse box, turn the power back on for
the fan whose frequency you are changing.
Step 6. Within 20 seconds of restoring power, push the Hi, Med, and
Lo buttons (in that order).
Note: All fans leave the factory set to ‘00000’.
WITHIN 20 SECONDS OF
TURNING THE FAN ON,
PRESS IN THIS ORDER TO
SET NEW FREQUENCY:
1. HI
2. MED
3. LO
1
2
3
CIRCUIT BREAKER
OR FUSE BOX
PRESS IN THIS ORDER TO SET NEW
FREQUENCY:
1. HI 2. MED 3. LO
DIP SWITCH
SET TO ‘01001’
DIP SWITCH
SET TO ‘10000’

CONTROL
(BACK)
Note: You may want to label your controls to
assure you do not mix them up.
WARNING: Do not turn the power off at the circuit breaker,
        
fan(s), as you may inadvertantly change the frequency set-
tings for it as well.
LO
MED
HI
LIGHT
FAN
STOP
REVERSE
1
2
3
Ve r s a •To u c h 2
®