LIGHTING INSTRUCTIONS
1. Make 2~3 oz. of leak solution by mixing one part liquid dishwasher detergent and three parts water. Noted: make
sure control knob is “OFF”.
2. Apply several drops of solution where the cylinder attaches to regulator, (see Figure 19), inspect the solution at
the connection looking for bubbles. If NO bubbles appear, the connection is secure. If bubbles appear, the
connection has the leak, disconnect the regulator, reconnect, perform another leak check. If you continue to see
bubbles after several attempts, cylinder valve is defective and should be returned to cylinder’s supplier.
3. Apply several drops of solution where natural gas fixture attaches to natural gas supply system connection
(see Figure 20), If NO bubbles appear, the connections are secure. If bubbles appear, the connection has the
leak, disconnect, reconnect, perform another leak check. If you continue to see bubbles after several attempts, the
conversion hose is defective and should replace with a new one.
4. Apply several drops of solution where gas valve attaches to bellows, (see Figure 21), where gas valve attaches to
regulator hose, (see Figure 22), and where inlet tube attaches to bellows, (see Figure 23). If NO bubbles appear,
the connections are secure. If bubbles appear, the connection has the leak, disconnect, reconnect, perform
another leak check. If you continue to see bubbles after several attempts, both parts are defective and should
replace with the new ones.
1. Push in gas control knob slightly and turn to “OFF”.
2. Turn gas control knob to “ON/MIN”.
3. Push in gas control knob all the way and hold. Continue to press the ignition button for 15 seconds.
4. If the burner does not light in 15 seconds, release the knob and it will pop back out. Wait 5 minutes before
attempting to light the burner again and repeat step 1 to 3.
WARNING: For your safety, read and follow the Lighting Instructions in this manual and in the Rating Plate on the
appliance. IMPROPER LIGHTING PROCEDURES COULD RESULT IN A FIRE HAZARD OR EXPLOSION
HAZARD OR PROPERTY DAMAGE, INJURY OR LOSS OF LIFE.
TO TURN OFF GAS
1. Push in gas control knob slightly and turn to “OFF”.
To perform a leak test:
gas valve / regulator hose connection (Figure 22) inlet tube / bellows connection (Figure 23)
Figure 24
gas control knob
ignition button