User's Manual

STATUS PAGE
The Status page contains information on the operation of the product. It is the default web page.
The following parameters are displayed:
Device Type: displays the type of Cyclone module that is currently being viewed. This field will let
the operator know the frequency band of the module, the protocol that it is utilizing, and the MAC
address of the module.
Software Version: displays the version of the software that is currently loaded into the module.
Please make note of this information when obtaining technical support.
FPGA Version: displays the version of the FPGA (field programmable gate array) that is
currently loaded into the module. Please make not of this information when obtaining technical
support.
Uptime: displays the length of time the module has been operating since power was applied.
System Time: displays the current time. If the access point module is connected to a Cluster
Management Module (CMM) then the time will be Greenwich Mean Time (GMT). Any subscriber
module that registers to the access point module will inherit the system time.
Ethernet Interface: displays the configuration of the Ethernet interface on the module.
Registered SM Count: displays the number of subscriber modules currently registered to the
access point module.
GPS Sync Pulse Status: displays the current status of the type of synchronization the access
point module is receiving. There are 3 values that could be displayed:
Generating sync: If the module is set to generate its own sync pulse then this message will
be displayed.
Receiving Sync: If the module is set to receive a sync pulse from an outside source (not
itself) and is actually receiving the pulse then this message will be displayed.
ERROR: No Sync Pulse: If the module is set to receive a sync pulse from an outside
source (not itself) and it is currently not receiving the pulse this message will be displayed.
Page 25
When this message is displayed the access point module will turn its transmitter off so as
to not create any self-interference within the Cyclone System.
Radio Slicing Value: displays information to be used be Cyclone technical support.
Radio Transmit Gain Setting: displays information to be used by Cyclone technical support.
Site Name: displays information relating to the name of the physical module. This parameter can
be set by the operator on the Configuration web page. This information is set into the sysName
SNMP MIB-II object and can be polled via a SNMP management server.
Site Contact: displays contact information for the physical module. This parameter can be set by
the operator on the Configuration web page. This information is set into the sysContact SNMP
MIBII object and can be polled via a SNMP management server.