Installation Guide
Rubber Washer (E)
Wire Connector
Turn off the power at fuse or circuit box.
Installation Steps
(A)
Hardware Package (inc luded):
Mounting Screw (
B
)
Dry wall screw (D) Decorative Nut (F)
Anchor (C)
Outlet Box
Wire
Connectors
(A)
Mounting Plate (J)
Main Fixture (H)
Rubber Washer (E)
Lock Nut
(K)
Fixture
Mounting
Screw
(G)
Mounting
Screw
(B)
Glass
(I)
Anchor (C )
Dry wall screw (D)
181115
Turn on the power at fuse or circuit box.
NOTES: 1. Before installing, consult local electrical codes for wiring and ground requirements.
2. Read and save this instruction.
1. Remove four lock nuts(K) to separate the mounting bracket from fixture.
2. Attach the mounting plate(J).
3. Pull out the outlet box wires and the house ground wire from the outlet box. Make wire connections using the wire
connectors(A):
a.The black wire from the fixture to the black wire from the power source.
b.The white wire from the fixture to the white wire from the power source.
c.Loop the supply ground wire around the ground screw on the mounting plate and tighten it in place. Connect the
fixture ground wire to the supply ground wire using a wire connector(A).
4. Attach the main fixture(H) to the mounting plate and fasten it with four lock nuts(K).
5. Secure the square glass(I) with four decorative nuts and rubber washers.
a) For wooden mounting place:
Attach the mounting plate(J) to the outlet box using two mounting screws(B) and secure the drywall screws
into the mounting holes of the mounting place.
b) For cement or drywall mounting place:
Hold the mounting plate to the outlet box and mark the drilling holes on the mounting place for drilling.
Hammer the anchors in the drilling holes until it’s flush with the ceiling wall. Fasten the mounting plate by driving
the dry wall screws(D) into the anchors(C).