Installation Guide

Back Plate
Fixture
070210
1. Thread two headless screws through the mounting plate, then secure them with four
lock nuts (two on each side of the mounting plate). Adjust the length of the headless
screws if necessary.
2. Attach the mounting plate to the outlet box by using two mounting screws.
3. Pull out the outlet wires and house grounding wire from the outlet box. Make wire
connections using the wire nuts:
---The black wire from the fixture to the black wire from the power source.
---The white wire from the fixture to the white wire from the power source.
---Attach the fixture grounding wire to the mounting plate with the green grounding
screw. Then connect it to the house grounding wire with a wire nut.
Carefully tuck the wires back into the outlet box.
4. Attach the back plate to the mounting plate by inserting the headless screws, then
secure it with bolt nuts.
5. Attach the candle tubes onto the sockets, then install bulbs (not included). See
relamping label at socket area or packaging for maximum allowed wattage.
6. Turn on the power at the main fuse or circuit breaker box.
ASSEMBLY AND INSTALLATION
INSTRUCTIONS
WARNING: BE SURE TO SHUT OFF POWER AT THE MAIN FUSE OR CIRCUIT
BREAKER BOX BEFORE INSTALLING OR SERVICING THIS FIXTURE.
NOTE: 1. Before installing, consult local electrical codes for wiring and grounding requirements.
2. READ AND SAVE THIS INSTRUCTION.
ED-OWD070 / OWD090
Bolt Nut
Candle Tube
Socket
Fixture Wire
Headless Screw
Lock Nut
Mounting Screw
Mounting Plate
Housing Grounding Wire
Fixture Grounding Wire
Outlet Box
Wire Nut
Green Grounding Screw

Summary of content (1 pages)