Installation Guide
A
C
B
Installation Steps
10’ Power Cable
12” Link Cord
Dry Wall Screw
Switch Label
Cable Clip
Turn off the power at fuse or circuit box.
160127
1. Find a suitable location to mount the fixture, make sure that
your 10 ft. power cord will reach the nearest electrical
outlet. The mounting surface should be a minimum of 1/2”
thick.
Note: The recommended mounting position for under-cabinet
use is towards the front edge of the cabinet. This provides
even light distribution across the countertop surface
(as shown in Fig. 1).
Page 1 / 4
Important to Know
1. Read all instructions carefully before installation and operation.
2. If you are not familiar with state and local electrical codes, it is recommended that you consult with a qualified electrician.
3. Units can be linked together in series from one power supply. Link up to 7 x 8" bar lights (#X0035 or X0036) together,
link up to 5 x 16" bar lights (#X0037 or X0038) together, link up to 3 x 21" bar lights (#X0039 or X0040) together, or link
combination of sizes together.
4. Do not use in wet locations, use indoors only.
5. Non-replaceable LEDs.
6. Caution: LEDs emit bright light. Avoid looking directly into the light source for prolonged periods to avoid eye damage.
7. Specification:
Important safety instructions.
1. Never use with an extension cord unless plug can be fully inserted.
2. Do not alter the plug.
3. Do not attempt to install fixture while it is plugged in.
ASSEMBLY AND INSTALLATION
INSTRUCTIONS
X0035 / X0036 / X0037 / X0038 / X0039 / X0040
NO.
1
3
5
Dimension(inch)
Total
Watts
Item #:
8
X0035/X0036
X0037/X0038
X0039/X0040
A
B
C
0.75
8
12
15
2.75
16
0.75
2.75
21
0.75
2.75
NOTE: 1. Before installing, consult local electrical codes for wiring and grounding requirements.
2. READ AND SAVE THESE INSTRUCTIONS.
Hardware Package (included):
Cabinet
Wall
Fig.1.
Counter Top
WARNING:
TO AVOID RISK OF ELECTRICAL SHOCK, BE SURE TO SHUT OFF