Specifications
Remote-Control CommandsGPS and Assisted GPS
136Operating Manual 1171.5248.12 ─ 15
Parameters:
<Source> INTernal | EXTernal | BEXTernal | OBASeband
INTernal
Triggering is executed by means of the Trigger command
SOURce:BB:GPS:TRIGger:EXECute or *TRG in the case of
remote control and by means of Execute Trigger in the case of
manual operation.
EXTernal
Triggering is executed by means of the signal on the TRIGGER 1
connector.
BEXTernal
Triggering is executed by means of the signal on the TRIGGER 2
connector.
OBASeband
Triggering is executed by means of the trigger signal from the
second path (two-path instruments only).
Example:
BB:GPS:TRIG:SING
selects a trigger mode that requires a trigger.
BB:GPS:TRIG:SOUR EXT
sets external triggering via the TRIGGER 1 connector.
[:SOURce<hw>]:BB:GPS:TRIGger[:EXTernal<ch>]:DELay <Delay>
Specifies the trigger delay (expressed as a number of chips) for external triggering.
Parameters:
<Delay> float
Range: 0.0 to 65535.0
Increment: 0.01 chip
*RST: 0.0 chips
Example:
BB:GPS:TRIG:SOUR EXT
sets an external trigger via the TRIGGER 1 connector.
BB:GPS:TRIG:DEL 50
sets a delay of 50 chips for the trigger.
[:SOURce<hw>]:BB:GPS:TRIGger[:EXTernal<ch>]:INHibit <Inhibit>
Specifies the number of chips by which a restart is to be inhibited following a trigger event.
Applies only in the case of external triggering.
Parameters:
<Inhibit> float
Range: 0 to 2^32-1
Increment: 1 chip
*RST: 0 chips
Trigger Settings